Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Boise State University |
---|---|
Assessment Year | 2017 |
Principal Product | Trailers |
NAICS | 336212 - Truck Trailer Manufacturing |
SIC | 3715 - Truck Trailers |
Sales | $100,000,000-$500,000,000 |
# of Employees | 305 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 1,500 Pieces |
Production Hrs. Annual | 4,020 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $133,298 | 2,739,363 | kWh | $0.05 |
Electricity Demand | $66,159 | 10,208 | kW-months/year | $6.48 |
Electricity Fees | $18,655 | - | $ | - |
Natural Gas | $52,857 | 7,699 | MMBtu | $6.87 |
TOTAL ENERGY COSTS | $270,969 | |||
RECOMMENDED SAVINGS* | $55,989 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,961 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $9,634 Cost: $1,202 |
$9,634 | 197,977 | - | - | - | - | - | - |
$9,634 197,977 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,164 Cost: $45,960 |
$2,784 | 57,199 | $1,380 | 216 | - | - | - | - |
$2,784 57,199 kWh |
$1,380 216 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,935 Cost: $15,234 |
$4,555 | 93,599 | $1,380 | 213 | - | - | - | - |
$4,555 93,599 kWh |
$1,380 213 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $9,156 Cost: $20,491 |
- | - | - | - | $9,156 | - | - | - |
- - kWh |
- - kW-months/year |
$9,156 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,362 Cost: $1,171 |
$3,880 | 79,666 | $1,482 | 229 | - | - | - | - |
$3,880 79,666 kWh |
$1,482 229 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,327 Cost: $128 |
$1,290 | 26,489 | $37 | 6 | - | - | - | - |
$1,290 26,489 kWh |
$37 6 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $9,891 Cost: $13,498 |
$6,858 | 147,166 | $3,033 | 468 | - | - | - | - |
$6,858 147,166 kWh |
$3,033 468 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR |
Savings: $10,520 Cost: $21,040 |
- | - | - | - | - | - | $10,520 | 1,541 |
- - kWh |
- - kW-months/year |
- - $ |
$10,520 1,541 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,989 Cost: $118,724 |
$29,001 | 602,096 | $7,312 | 1,132 | $9,156 | - | $10,520 | 1,541 | $29,001 602,096 kWh |
$7,312 1,132 kW-months/year |
$9,156 - $ |
$10,520 1,541 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,961 Cost: $1,330 |
$10,924 | 224,466 | $37 | 6 | - | - | - | - | $10,924 224,466 kWh |
$37 6 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |