Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of North Carolina, Charlotte |
---|---|
Assessment Year | 2024 |
Principal Product | bottled water |
NAICS | 312112 - Bottled Water Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $5,000,000-$10,000,000 |
# of Employees | 26 |
Plant Area (Sq.Ft.) | 52,000 |
Annual Production | 18,000 Thousand Gallons |
Production Hrs. Annual | 4,420 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $36,434 | 355,031 | kWh | $0.10 |
Electricity Demand | $15,878 | 1,161 | kW-months/year | $13.67 |
Electricity Fees | $678 | - | $ | - |
Natural Gas | $6,053 | 459 | MMBtu | $13.20 |
TOTAL ENERGY COSTS | $59,043 | |||
RECOMMENDED SAVINGS* | $34,674 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $1,534 Cost: $7,000 |
$845 | 8,208 | $689 | 50 | - | - |
$845 8,208 kWh |
$689 50 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,395 Cost: $4,578 |
$6,156 | 59,769 | $2,239 | 164 | - | - |
$6,156 59,769 kWh |
$2,239 164 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,484 Cost: $1,000 |
$8,484 | 82,368 | - | - | - | - |
$8,484 82,368 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,601 Cost: $4,550 |
- | - | - | - | $3,601 | 273 |
- - kWh |
- - kW-months/year |
$3,601 273 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $4,795 Cost: $2,800 |
$4,795 | 46,553 | - | - | - | - |
$4,795 46,553 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,865 Cost: - |
$5,782 | 56,134 | $2,083 | 152 | - | - |
$5,782 56,134 kWh |
$2,083 152 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,674 Cost: $19,928 |
$26,062 | 253,032 | $5,011 | 367 | $3,601 | 273 | $26,062 253,032 kWh |
$5,011 367 kW-months/year |
$3,601 273 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |