Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2023
Principal Product Academic Services
NAICS 611110 - Elementary and Secondary Schools
SIC 8211 - Elementary And Secondary Schools
Sales $1,000,000-$5,000,000
# of Employees 68
Plant Area (Sq.Ft.) 43,000
Annual Production 1 Units
Production Hrs. Annual 3,443
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $162,441 579,000 kWh $0.28
Electricity Fees $20,479 - $ -
TOTAL ENERGY COSTS $184,506
RECOMMENDED SAVINGS* $113,389 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$42,109
Cost:
$26,411
$42,109 150,068 $42,109
150,068
kWh
02: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$14,087
Cost:
$30,000
$14,087 50,203 $14,087
50,203
kWh
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$12,997
Cost:
$44,000
$12,997 46,320 $12,997
46,320
kWh
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$10,477
Cost:
$35,642
$10,477 37,338 $10,477
37,338
kWh
05: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$9,748
Cost:
$5,000
$9,748 34,740 $9,748
34,740
kWh
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$8,621
Cost:
$5,200
$8,621 30,725 $8,621
30,725
kWh
07: 2.7262 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS Savings:
$8,233
Cost:
$4,400
$8,233 29,340 $8,233
29,340
kWh
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$7,117
Cost:
$3,300
$7,117 24,480 $7,117
24,480
kWh
TOTAL RECOMMENDED Savings:
$113,389
Cost:
$153,953
$113,389 403,214 $113,389
403,214
kWh
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - -
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage