IAC logo
IAC Assessment: CI0020
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0020
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2023
Principal Product PVC and CPVC Piping
NAICS 326122 - Plastics Pipe and Pipe Fitting Manufacturing
SIC 3084 - Plastics Pipe
Sales $10,000,000-$50,000,000
# of Employees 37
Plant Area (Sq.Ft.) 166,000
Annual Production 19,000,000 Pounds
Production Hrs. Annual 6,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $512,777 2,110,307 kWh $0.24
Natural Gas $124,876 26,095 MMBtu $4.79
LPG $96,000 395 MMBtu $243.04
TOTAL ENERGY COSTS $733,653
RECOMMENDED SAVINGS* $235,117 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG
$ kWh $ MMBtu $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$92,262
Cost:
$487,880
$92,262 379,680 - - - - $92,262
379,680
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$76,570
Cost:
$180,000
$(-19,430) (-79,960) - - $96,000 395 $(-19,430)
(-79,960)
kWh
-
-
MMBtu
$96,000
395
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$55,349
Cost:
$45,000
$55,349 227,774 - - - - $55,349
227,774
kWh
-
-
MMBtu
-
-
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$6,503
Cost:
$2,870
$6,503 26,666 - - - - $6,503
26,666
kWh
-
-
MMBtu
-
-
MMBtu
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$3,187
Cost:
$20,000
- - $3,187 666 - - -
-
kWh
$3,187
666
MMBtu
-
-
MMBtu
06: 2.7134 USE PHOTOCELL CONTROLS Savings:
$1,246
Cost:
$750
$1,246 5,088 - - - - $1,246
5,088
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$235,117
Cost:
$736,500
$135,930 559,248 $3,187 666 $96,000 395 $135,930
559,248
kWh
$3,187
666
MMBtu
$96,000
395
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG