Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of California, Irvine |
---|---|
Assessment Year | 2023 |
Principal Product | Industrial Laundry Service |
NAICS | 812332 - Industrial Launderers |
SIC | 7218 - Industrial Launderers |
Sales | <$500,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 58,063 |
Annual Production | 1 Units |
Production Hrs. Annual | 3,210 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $62,427 | 692,640 | kWh | $0.09 |
Electricity Demand | $36,997 | 7,578 | kW-months/year | $4.88 |
Electricity Fees | $34,809 | - | $ | - |
Natural Gas | $356,242 | 20,815 | MMBtu | $17.11 |
LPG | $32,000 | 6,020 | MMBtu | $5.32 |
TOTAL ENERGY COSTS | $522,475 | |||
RECOMMENDED SAVINGS* | $79,876 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1224 REPLACE BOILER |
Savings: $40,642 Cost: $20,000 |
$(-3,239) | (-35,952) | $(-328) | (-67) | $44,209 | 2,583 | - | - | - | - | - | - |
$(-3,239) (-35,952) kWh |
$(-328) (-67) kW-months/year |
$44,209 2,583 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8227 ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION |
Savings: $21,942 Cost: $60,000 |
$(-9,619) | (-106,763) | $(-439) | (-90) | - | - | $32,000 | 6,020 | - | - | - | - |
$(-9,619) (-106,763) kWh |
$(-439) (-90) kW-months/year |
- - MMBtu |
$32,000 6,020 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $6,141 Cost: $80,118 |
$5,608 | 62,244 | $533 | 109 | - | - | - | - | - | - | - | - |
$5,608 62,244 kWh |
$533 109 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,866 Cost: $2,700 |
$2,360 | 26,194 | $930 | 191 | - | - | - | - | $262 | - | $314 | - |
$2,360 26,194 kWh |
$930 191 kW-months/year |
- - MMBtu |
- - MMBtu |
$262 - $ |
$314 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,454 Cost: $2,400 |
$2,999 | 33,286 | $455 | 93 | - | - | - | - | - | - | - | - |
$2,999 33,286 kWh |
$455 93 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,873 Cost: $8,074 |
$2,389 | 26,521 | $484 | 99 | - | - | - | - | - | - | - | - |
$2,389 26,521 kWh |
$484 99 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $500 Cost: $2,000 |
$416 | 4,614 | $84 | 17 | - | - | - | - | - | - | - | - |
$416 4,614 kWh |
$84 17 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7262 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS |
Savings: $458 Cost: $400 |
$458 | 5,088 | - | - | - | - | - | - | - | - | - | - |
$458 5,088 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,876 Cost: $175,692 |
$1,372 | 15,232 | $1,719 | 352 | $44,209 | 2,583 | $32,000 | 6,020 | $262 | - | $314 | - | $1,372 15,232 kWh |
$1,719 352 kW-months/year |
$44,209 2,583 MMBtu |
$32,000 6,020 MMBtu |
$262 - $ |
$314 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Personnel Changes | One-time Revenue or Avoided Cost |