Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of California, Irvine |
---|---|
Assessment Year | 2024 |
Principal Product | Table Linen Manufacturing |
NAICS | 313310 - Textile and Fabric Finishing Mills |
SIC | 2299 - Textile Goods, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 57,000 |
Annual Production | 100,000 Pieces |
Production Hrs. Annual | 1,664 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $42,845 | 352,920 | kWh | $0.12 |
Electricity Demand | $18,596 | 1,551 | kW-months/year | $11.99 |
Electricity Fees | $14,067 | - | $ | - |
Natural Gas | $64,552 | 6,455 | MMBtu | $10.00 |
TOTAL ENERGY COSTS | $140,060 | |||
RECOMMENDED SAVINGS* | $66,904 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $21,581 Cost: $101,332 |
$18,298 | 150,726 | $3,283 | 274 | - | - |
$18,298 150,726 kWh |
$3,283 274 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $15,868 Cost: $1,600 |
- | - | - | - | $15,868 | 1,587 |
- - kWh |
- - kW-months/year |
$15,868 1,587 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $8,384 Cost: $3,000 |
$5,021 | 41,367 | $3,363 | 281 | - | - |
$5,021 41,367 kWh |
$3,363 281 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $4,601 Cost: $18,900 |
- | - | - | - | $4,601 | 460 |
- - kWh |
- - kW-months/year |
$4,601 460 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,265 Cost: $2,565 |
- | - | - | - | $4,265 | 427 |
- - kWh |
- - kW-months/year |
$4,265 427 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,914 Cost: $1,600 |
$2,017 | 16,617 | $1,897 | 158 | - | - |
$2,017 16,617 kWh |
$1,897 158 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $3,830 Cost: $1,500 |
$1,168 | 9,620 | $2,662 | 222 | - | - |
$1,168 9,620 kWh |
$2,662 222 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $2,431 Cost: $4,000 |
- | - | - | - | $2,431 | 243 |
- - kWh |
- - kW-months/year |
$2,431 243 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,030 Cost: $5,000 |
- | - | - | - | $2,030 | 203 |
- - kWh |
- - kW-months/year |
$2,030 203 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,904 Cost: $139,497 |
$26,504 | 218,330 | $11,205 | 935 | $29,195 | 2,920 | $26,504 218,330 kWh |
$11,205 935 kW-months/year |
$29,195 2,920 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |