Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2024
Principal Product Table Linen Manufacturing
NAICS 313310 - Textile and Fabric Finishing Mills
SIC 2299 - Textile Goods, Nec
Sales $10,000,000-$50,000,000
# of Employees 95
Plant Area (Sq.Ft.) 57,000
Annual Production 100,000 Pieces
Production Hrs. Annual 1,664
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $42,845 352,920 kWh $0.12
Electricity Demand $18,596 1,551 kW-months/year $11.99
Electricity Fees $14,067 - $ -
Natural Gas $64,552 6,455 MMBtu $10.00
TOTAL ENERGY COSTS $140,060
RECOMMENDED SAVINGS* $66,904 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$21,581
Cost:
$101,332
$18,298 150,726 $3,283 274 - - $18,298
150,726
kWh
$3,283
274
kW-months/year
-
-
MMBtu
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$15,868
Cost:
$1,600
- - - - $15,868 1,587 -
-
kWh
-
-
kW-months/year
$15,868
1,587
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$8,384
Cost:
$3,000
$5,021 41,367 $3,363 281 - - $5,021
41,367
kWh
$3,363
281
kW-months/year
-
-
MMBtu
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$4,601
Cost:
$18,900
- - - - $4,601 460 -
-
kWh
-
-
kW-months/year
$4,601
460
MMBtu
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,265
Cost:
$2,565
- - - - $4,265 427 -
-
kWh
-
-
kW-months/year
$4,265
427
MMBtu
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$3,914
Cost:
$1,600
$2,017 16,617 $1,897 158 - - $2,017
16,617
kWh
$1,897
158
kW-months/year
-
-
MMBtu
07: 2.7134 USE PHOTOCELL CONTROLS Savings:
$3,830
Cost:
$1,500
$1,168 9,620 $2,662 222 - - $1,168
9,620
kWh
$2,662
222
kW-months/year
-
-
MMBtu
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$2,431
Cost:
$4,000
- - - - $2,431 243 -
-
kWh
-
-
kW-months/year
$2,431
243
MMBtu
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,030
Cost:
$5,000
- - - - $2,030 203 -
-
kWh
-
-
kW-months/year
$2,030
203
MMBtu
TOTAL RECOMMENDED Savings:
$66,904
Cost:
$139,497
$26,504 218,330 $11,205 935 $29,195 2,920 $26,504
218,330
kWh
$11,205
935
kW-months/year
$29,195
2,920
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas