Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1986
Principal Product POTATO & CORN SNACK FOOD
NAICS n/a
SIC 2099 - Food Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 24,000,000 Pounds
Production Hrs. Annual 2,210
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $119,977 2,398,886 kWh $0.05
Natural Gas $324,364 72,740 MMBtu $4.46
TOTAL ENERGY COSTS $444,341
RECOMMENDED SAVINGS* $56,398 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $44,259
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$34,952
Cost:
$300
- - $34,952 7,837 -
-
kWh
$34,952
7,837
MMBtu
02: 2.2428 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC Savings:
$6,532
Cost:
$12,000
- - $6,532 1,465 -
-
kWh
$6,532
1,465
MMBtu
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$3,339
Cost:
$800
$3,339 66,823 - - $3,339
66,823
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$667
Cost:
$150
$667 13,189 - - $667
13,189
kWh
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$877
Cost:
$400
- - $877 197 -
-
kWh
$877
197
MMBtu
06: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$621
Cost:
-
$621 12,309 - - $621
12,309
kWh
-
-
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$314
Cost:
$50
$314 6,155 - - $314
6,155
kWh
-
-
MMBtu
08: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$2,338
Cost:
$160
- - $2,338 524 -
-
kWh
$2,338
524
MMBtu
09: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$770
Cost:
$1,380
- - $770 173 -
-
kWh
$770
173
MMBtu
10: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,248
Cost:
$55
$97 2,052 $5,151 1,155 $97
2,052
kWh
$5,151
1,155
MMBtu
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$740
Cost:
$655
$740 14,947 - - $740
14,947
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$56,398
Cost:
$15,950
$5,778 115,475 $50,620 11,351 $5,778
115,475
kWh
$50,620
11,351
MMBtu
TOTAL IMPLEMENTED Savings:
$44,259
Cost:
$1,370
$1,818 36,343 $42,441 9,516 $1,818
36,343
kWh
$42,441
9,516
MMBtu
Savings
Cost
$ kWh $ MMBtu