Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1986
Principal Product PORTLAND CEMENT
NAICS n/a
SIC 3241 - Cement, Hydraulic
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 0
Annual Production 500,000 Tons
Production Hrs. Annual 8,736
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,928,654 68,867,234 kWh $0.04
Natural Gas $1,433,667 344,696 MMBtu $4.16
Coal $2,336,000 2,029,400 MMBtu $1.15
TOTAL ENERGY COSTS $6,698,321
RECOMMENDED SAVINGS* $1,378,290 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $127,486
#|Description Savings
Cost
Status Electricity Usage Natural Gas Coal Electricity Usage Natural Gas Coal
$ kWh $ MMBtu $ MMBtu
01: 2.3413 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT Savings:
$1,207,312
Cost:
$5,000,000
$1,315,044 43,800,118 - - $(-107,732) (-80,397) $1,315,044
43,800,118
kWh
-
-
MMBtu
$(-107,732)
(-80,397)
MMBtu
02: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$56,931
Cost:
-
$56,931 1,339,097 - - - - $56,931
1,339,097
kWh
-
-
MMBtu
-
-
MMBtu
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$43,492
Cost:
$37,500
- - - - $43,492 32,457 -
-
kWh
-
-
MMBtu
$43,492
32,457
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$26,207
Cost:
$7,000
$26,207 616,354 - - - - $26,207
616,354
kWh
-
-
MMBtu
-
-
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$13,012
Cost:
$12,000
$13,012 305,979 - - - - $13,012
305,979
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,423
Cost:
$46
$754 17,878 $2,669 1,043 - - $754
17,878
kWh
$2,669
1,043
MMBtu
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$25,097
Cost:
$3,098
$25,097 590,270 - - - - $25,097
590,270
kWh
-
-
MMBtu
-
-
MMBtu
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,816
Cost:
$1,000
- - $2,816 1,100 - - -
-
kWh
$2,816
1,100
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$1,378,290
Cost:
$5,060,644
$1,437,045 46,669,696 $5,485 2,143 $(-64,240) (-47,940) $1,437,045
46,669,696
kWh
$5,485
2,143
MMBtu
$(-64,240)
(-47,940)
MMBtu
TOTAL IMPLEMENTED Savings:
$127,486
Cost:
$23,144
$122,001 2,869,578 $5,485 2,143 - - $122,001
2,869,578
kWh
$5,485
2,143
MMBtu
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas Coal Electricity Usage Natural Gas Coal