IAC logo
IAC Assessment: CO0114
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0114
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1988
Principal Product GALVANIZED STEEL PARTS
NAICS n/a
SIC 3479 - Metal Coating And Allied Services
Sales $1,000,000-$5,000,000
# of Employees 25
Plant Area (Sq.Ft.) 0
Annual Production 10,000 Tons
Production Hrs. Annual 4,420
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $18,611 368,113 kWh $0.05
Natural Gas $89,014 21,816 MMBtu $4.08
TOTAL ENERGY COSTS $107,625
RECOMMENDED SAVINGS* $51,443 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $36,096
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$216
Cost:
$100
$216 4,396 - - $216
4,396
kWh
-
-
MMBtu
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,655
Cost:
$1,545
- - $1,655 406 -
-
kWh
$1,655
406
MMBtu
03: 2.2514 COVER OPEN TANKS Savings:
$7,093
Cost:
$1,400
- - $7,093 1,739 -
-
kWh
$7,093
1,739
MMBtu
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,783
Cost:
$2,400
- - $2,783 682 -
-
kWh
$2,783
682
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,713
Cost:
$1,700
- - $1,713 420 -
-
kWh
$1,713
420
MMBtu
06: 2.2514 COVER OPEN TANKS Savings:
$29,547
Cost:
$4,600
- - $29,547 7,242 -
-
kWh
$29,547
7,242
MMBtu
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,311
Cost:
$12,500
- - $7,311 1,792 -
-
kWh
$7,311
1,792
MMBtu
08: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$903
Cost:
$100
- - $903 229 -
-
kWh
$903
229
MMBtu
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$182
Cost:
$150
- - $182 45 -
-
kWh
$182
45
MMBtu
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$40
Cost:
$97
$40 879 - - $40
879
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$51,443
Cost:
$24,592
$256 5,275 $51,187 12,555 $256
5,275
kWh
$51,187
12,555
MMBtu
TOTAL IMPLEMENTED Savings:
$36,096
Cost:
$10,495
$216 4,396 $35,880 8,795 $216
4,396
kWh
$35,880
8,795
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas