Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1989
Principal Product REFINED CADMIUM INGOTS
NAICS n/a
SIC 3339 - Primary Nonferrous Metals, Nec
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 0
Annual Production 1,080,000 Pounds
Production Hrs. Annual 8,736
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $167,182 3,427,022 kWh $0.05
Natural Gas $210,170 59,783 MMBtu $3.52
TOTAL ENERGY COSTS $377,352
RECOMMENDED SAVINGS* $46,299 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $43,755
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$33,200
Cost:
$6,700
- - $33,200 - -
-
kWh
$33,200
-
MMBtu
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,410
Cost:
$5,000
$1,410 38,101 - - $1,410
38,101
kWh
-
-
MMBtu
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$351
Cost:
$3,460
- - $351 123 -
-
kWh
$351
123
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,887
Cost:
$4,162
$2,887 59,203 - - $2,887
59,203
kWh
-
-
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,494
Cost:
$2,200
- - $4,494 1,577 -
-
kWh
$4,494
1,577
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$2,193
Cost:
$10,000
- - $2,193 769 -
-
kWh
$2,193
769
MMBtu
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$800
Cost:
$700
- - $800 281 -
-
kWh
$800
281
MMBtu
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$657
Cost:
$750
- - $657 231 -
-
kWh
$657
231
MMBtu
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$307
Cost:
$359
$307 6,448 - - $307
6,448
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$46,299
Cost:
$33,331
$4,604 103,752 $41,695 2,981 $4,604
103,752
kWh
$41,695
2,981
MMBtu
TOTAL IMPLEMENTED Savings:
$43,755
Cost:
$19,871
$4,604 103,752 $39,151 2,089 $4,604
103,752
kWh
$39,151
2,089
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas