Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1989 |
Principal Product | GRANULATED SUGAR |
NAICS | n/a |
SIC | 2063 - Beet Sugar |
Sales | $10,000,000-$50,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 500,000 Tons |
Production Hrs. Annual | 3,120 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $323,285 | 10,536,636 | kWh | $0.03 |
Natural Gas | $192,590 | 59,596 | MMBtu | $3.23 |
Fuel Oil #2 | $345,723 | 181,149 | MMBtu | $1.91 |
Coal | $889,564 | 533,288 | MMBtu | $1.67 |
TOTAL ENERGY COSTS | $1,751,162 | |||
RECOMMENDED SAVINGS* | $55,681 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $47,972 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Coal | Electricity Usage | Natural Gas | Coal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $32,873 Cost: $4,000 |
- | - | $9,457 | 2,892 | $23,416 | 12,937 |
- - kWh |
$9,457 2,892 MMBtu |
$23,416 12,937 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $7,709 Cost: $3,000 |
- | - | - | - | $7,709 | 4,259 |
- - kWh |
- - MMBtu |
$7,709 4,259 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,778 Cost: $1,200 |
$2,778 | 90,563 | - | - | - | - |
$2,778 90,563 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $9,866 Cost: $15,850 |
- | - | $1,783 | 552 | $8,083 | 4,466 |
- - kWh |
$1,783 552 MMBtu |
$8,083 4,466 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,427 Cost: $1,373 |
$2,427 | 79,132 | - | - | - | - |
$2,427 79,132 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $28 Cost: $92 |
$28 | 879 | - | - | - | - |
$28 879 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,681 Cost: $25,515 |
$5,233 | 170,574 | $11,240 | 3,444 | $39,208 | 21,662 | $5,233 170,574 kWh |
$11,240 3,444 MMBtu |
$39,208 21,662 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $47,972 Cost: $22,515 |
$5,233 | 170,574 | $11,240 | 3,444 | $31,499 | 17,403 | $5,233 170,574 kWh |
$11,240 3,444 MMBtu |
$31,499 17,403 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Coal | Electricity Usage | Natural Gas | Coal |