Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1994
Principal Product fabricated metal parts
NAICS n/a
SIC 3599 - Industrial Machinery, Nec
Sales $1,000,000-$5,000,000
# of Employees 125
Plant Area (Sq.Ft.) 80,000
Annual Production 1,666,000 Pounds
Production Hrs. Annual 4,290
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $79,790 1,619,871 kWh $0.05
Natural Gas $38,410 10,081 MMBtu $3.81
TOTAL ENERGY COSTS $118,200
RECOMMENDED SAVINGS* $64,030 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,860
#|Description Savings
Cost
Status Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Gaseous Waste Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Gaseous Waste
$ kWh $ MMBtu $ gal $ lb $ lb
01: 3.2124 CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS Savings:
$53,800
Cost:
$7,000
- - - - - - $2,000 15,500 $51,800 1,840 -
-
kWh
-
-
MMBtu
-
-
gal
$2,000
15,500
lb
$51,800
1,840
lb
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,400
Cost:
$570
$3,400 68,875 - - - - - - - - $3,400
68,875
kWh
-
-
MMBtu
-
-
gal
-
-
lb
-
-
lb
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,320
Cost:
$3,890
$2,320 47,186 - - - - - - - - $2,320
47,186
kWh
-
-
MMBtu
-
-
gal
-
-
lb
-
-
lb
04: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER Savings:
$2,020
Cost:
$3,500
- - - - $830 2,840 - - $1,190 990 -
-
kWh
-
-
MMBtu
$830
2,840
gal
-
-
lb
$1,190
990
lb
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$2,030
Cost:
$5,700
- - $2,030 637 - - - - - - -
-
kWh
$2,030
637
MMBtu
-
-
gal
-
-
lb
-
-
lb
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$460
Cost:
$400
$460 9,379 - - - - - - - - $460
9,379
kWh
-
-
MMBtu
-
-
gal
-
-
lb
-
-
lb
TOTAL RECOMMENDED Savings:
$64,030
Cost:
$21,060
$6,180 125,440 $2,030 637 $830 2,840 $2,000 15,500 $52,990 2,830 $6,180
125,440
kWh
$2,030
637
MMBtu
$830
2,840
gal
$2,000
15,500
lb
$52,990
2,830
lb
TOTAL IMPLEMENTED Savings:
$3,860
Cost:
$970
$3,860 78,254 - - - - - - - - $3,860
78,254
kWh
-
-
MMBtu
-
-
gal
-
-
lb
-
-
lb
Savings
Cost
$ kWh $ MMBtu $ gal $ lb $ lb
Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Gaseous Waste Electricity Usage Natural Gas Other Liquid (haz) Solid Waste (non-haz) Gaseous Waste