Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1995
Principal Product Pickles
NAICS n/a
SIC 2035 - Pickles, Sauces, And Salad Dressings
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 200,000
Annual Production 4,000,000 BBL
Production Hrs. Annual 7,268
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $144,098 1,926,143 kWh $0.07
Natural Gas $192,465 60,711 MMBtu $3.17
TOTAL ENERGY COSTS $336,563
RECOMMENDED SAVINGS* $21,940 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,480
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,670
Cost:
$23,310
$10,670 171,747 - - $10,670
171,747
kWh
-
-
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,330
Cost:
$6,500
- - $4,330 1,380 -
-
kWh
$4,330
1,380
MMBtu
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,790
Cost:
$1,040
- - $2,790 887 -
-
kWh
$2,790
887
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,460
Cost:
$3,320
- - $2,460 784 -
-
kWh
$2,460
784
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,230
Cost:
$530
$1,230 20,809 - - $1,230
20,809
kWh
-
-
MMBtu
06: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$460
Cost:
$160
- - $460 102 -
-
kWh
$460
102
MMBtu
TOTAL RECOMMENDED Savings:
$21,940
Cost:
$34,860
$11,900 192,556 $10,040 3,153 $11,900
192,556
kWh
$10,040
3,153
MMBtu
TOTAL IMPLEMENTED Savings:
$19,480
Cost:
$31,540
$11,900 192,556 $7,580 2,369 $11,900
192,556
kWh
$7,580
2,369
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas