Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1996 |
Principal Product | bottom-dump trailers |
NAICS | n/a |
SIC | 3715 - Truck Trailers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 26,000 |
Annual Production | 450 Pieces |
Production Hrs. Annual | 4,147 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,396 | 895,662 | kWh | $0.05 |
Electricity Demand | $19,473 | 3,073 | kW-months/year | $6.34 |
Natural Gas | $33,357 | 6,096 | MMBtu | $5.47 |
TOTAL ENERGY COSTS | $107,336 | |||
RECOMMENDED SAVINGS* | $19,610 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,570 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $6,620 Cost: $12,550 |
- | - | - | - | - | - | - | - | $130 | (-6,250) | $6,490 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$130 (-6,250) lb |
$6,490 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $10,060 Cost: $47,840 |
$7,300 | 150,645 | $2,760 | 435 | - | - | - | - | - | - | - | - |
$7,300 150,645 kWh |
$2,760 435 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,640 Cost: $1,310 |
- | - | - | - | $1,640 | 302 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,640 302 MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $590 Cost: $1,065 |
$400 | 8,206 | $190 | 30 | - | - | - | - | - | - | - | - |
$400 8,206 kWh |
$190 30 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $510 Cost: $140 |
$360 | 7,620 | $150 | 23 | - | - | - | - | - | - | - | - |
$360 7,620 kWh |
$150 23 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $190 Cost: - |
- | - | - | - | - | - | $550 | 80 | - | - | $(-360) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$550 80 gal |
- - lb |
$(-360) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,610 Cost: $62,905 |
$8,060 | 166,471 | $3,100 | 488 | $1,640 | 302 | $550 | 80 | $130 | (-6,250) | $6,130 | - | $8,060 166,471 kWh |
$3,100 488 kW-months/year |
$1,640 302 MMBtu |
$550 80 gal |
$130 (-6,250) lb |
$6,130 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,570 Cost: $47,980 |
$7,660 | 158,265 | $2,910 | 458 | - | - | - | - | - | - | - | - | $7,660 158,265 kWh |
$2,910 458 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (haz) | Ancillary Material Cost |