Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1996 |
Principal Product | food service equipment |
NAICS | n/a |
SIC | 3589 - Service Industry Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 210,000 |
Annual Production | 4,000,000 Pounds |
Production Hrs. Annual | 4,250 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,696 | 2,341,442 | kWh | $0.02 |
Electricity Demand | $55,251 | 6,268 | kW-months/year | $8.81 |
Electricity Fees | $677 | - | $ | - |
Natural Gas | $48,288 | 13,744 | MMBtu | $3.51 |
TOTAL ENERGY COSTS | $170,252 | |||
RECOMMENDED SAVINGS* | $43,520 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $12,310 Cost: $8,000 |
- | - | - | - | - | - | - | - | $12,310 | 50,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$12,310 50,000 lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,050 Cost: $21,648 |
$3,068 | 141,559 | $3,982 | 452 | - | - | - | - | - | - | - | - | - | - | - | - |
$3,068 141,559 kWh |
$3,982 452 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $9,340 Cost: $10,650 |
$3,400 | 156,800 | $8,290 | 941 | $(-2,350) | (-669) | - | - | - | - | - | - | - | - | - | - |
$3,400 156,800 kWh |
$8,290 941 kW-months/year |
$(-2,350) (-669) MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $4,480 Cost: $1,000 |
- | - | - | - | - | - | - | - | - | - | $1,710 | 2,360 | - | - | $2,770 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$1,710 2,360 lb |
- - $ |
$2,770 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $3,060 Cost: $33,280 |
$930 | 42,790 | $2,130 | 242 | - | - | - | - | - | - | - | - | - | - | - | - |
$930 42,790 kWh |
$2,130 242 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,750 Cost: $1,800 |
- | - | - | - | $2,750 | 783 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,750 783 MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,540 Cost: $8,500 |
$800 | 36,928 | $740 | 83 | - | - | - | - | - | - | - | - | - | - | - | - |
$800 36,928 kWh |
$740 83 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER |
Savings: $1,340 Cost: $1,000 |
- | - | - | - | - | - | $680 | 90 | - | - | - | - | $330 | - | $330 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$680 90 gal |
- - lb |
- - lb |
$330 - $ |
$330 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,220 Cost: $1,500 |
- | - | - | - | $1,220 | 346 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,220 346 MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $220 Cost: $1,170 |
- | - | - | - | - | - | $600 | 72 | - | (-24) | - | - | - | - | $(-380) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$600 72 gal |
- (-24) lb |
- - lb |
- - $ |
$(-380) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $210 Cost: $300 |
$100 | 4,396 | $110 | 13 | - | - | - | - | - | - | - | - | - | - | - | - |
$100 4,396 kWh |
$110 13 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,520 Cost: $88,848 |
$8,298 | 382,473 | $15,252 | 1,731 | $1,620 | 460 | $1,280 | 162 | $12,310 | 49,976 | $1,710 | 2,360 | $330 | - | $2,720 | - | $8,298 382,473 kWh |
$15,252 1,731 kW-months/year |
$1,620 460 MMBtu |
$1,280 162 gal |
$12,310 49,976 lb |
$1,710 2,360 lb |
$330 - $ |
$2,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,220 Cost: $10,800 |
$100 | 4,396 | $110 | 13 | $1,220 | 346 | - | - | $12,310 | 50,000 | $1,710 | 2,360 | - | - | $2,770 | - | $100 4,396 kWh |
$110 13 kW-months/year |
$1,220 346 MMBtu |
- - gal |
$12,310 50,000 lb |
$1,710 2,360 lb |
- - $ |
$2,770 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost |