Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1996 |
Principal Product | ski lift systems |
NAICS | n/a |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 32,000 |
Annual Production | 15 Pieces |
Production Hrs. Annual | 3,003 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,710 | 570,926 | kWh | $0.03 |
Electricity Demand | $26,729 | 2,660 | kW-months/year | $10.05 |
Electricity Fees | $(-228) | - | $ | - |
Natural Gas | $5,413 | 1,525 | MMBtu | $3.55 |
TOTAL ENERGY COSTS | $53,334 | |||
RECOMMENDED SAVINGS* | $7,835 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $380 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $4,000 Cost: $1,950 |
- | - | - | - | - | - | - | - | - | - | $4,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$4,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER |
Savings: $2,260 Cost: $1,000 |
- | - | - | - | - | - | $150 | 60 | $760 | - | $1,350 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$150 60 gal |
$760 - $ |
$1,350 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $1,070 Cost: $1,400 |
- | - | - | - | - | - | $1,380 | 80 | - | - | $(-310) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,380 80 gal |
- - $ |
$(-310) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $125 Cost: $188 |
$55 | 1,465 | $70 | 7 | - | - | - | - | - | - | - | - |
$55 1,465 kWh |
$70 7 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $380 Cost: $650 |
- | - | - | - | $380 | 107 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$380 107 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,835 Cost: $5,188 |
$55 | 1,465 | $70 | 7 | $380 | 107 | $1,530 | 140 | $760 | - | $5,040 | - | $55 1,465 kWh |
$70 7 kW-months/year |
$380 107 MMBtu |
$1,530 140 gal |
$760 - $ |
$5,040 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $380 Cost: $650 |
- | - | - | - | $380 | 107 | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
$380 107 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost |