Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | kitchen and bath countertops |
NAICS | n/a |
SIC | 2434 - Wood Kitchen Cabinets |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 42,500 |
Annual Production | 637 Thousand Feet |
Production Hrs. Annual | 2,600 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $16,846 | 729,191 | kWh | $0.02 |
Electricity Demand | $33,460 | 2,481 | kW-months/year | $13.49 |
Electricity Fees | $309 | - | $ | - |
Natural Gas | $15,857 | 4,354 | MMBtu | $3.64 |
TOTAL ENERGY COSTS | $116,102 | |||
RECOMMENDED SAVINGS* | $187,754 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,204 Cost: $7,390 |
$537 | 29,601 | $1,667 | 115 | - | - | - | - | - | - | - | - |
$537 29,601 kWh |
$1,667 115 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,310 Cost: $540 |
$500 | 27,550 | $1,810 | 127 | - | - | - | - | - | - | - | - |
$500 27,550 kWh |
$1,810 127 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $960 Cost: $380 |
$210 | 11,430 | $750 | 53 | - | - | - | - | - | - | - | - |
$210 11,430 kWh |
$750 53 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $490 Cost: $1,870 |
- | - | - | - | $490 | 151 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$490 151 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1121 USE MORE EFFICIENT ADHESIVE APPLICATORS |
Savings: $16,000 Cost: $30,000 |
- | - | - | - | - | - | - | 3,700 | $16,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- 3,700 lb |
$16,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $250 Cost: - |
- | - | - | - | - | - | $250 | 6,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$250 6,000 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $156,000 Cost: $7,470 |
- | - | - | - | - | - | - | - | - | - | $156,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$156,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.123 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING |
Savings: $9,540 Cost: $1,350 |
- | - | - | - | - | - | $300 | 18,270 | $6,720 | - | $2,520 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$300 18,270 lb |
$6,720 - $ |
$2,520 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $187,754 Cost: $49,000 |
$1,247 | 68,581 | $4,227 | 295 | $490 | 151 | $550 | 27,970 | $22,720 | - | $158,520 | - | $1,247 68,581 kWh |
$4,227 295 kW-months/year |
$490 151 MMBtu |
$550 27,970 lb |
$22,720 - $ |
$158,520 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||