Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | dried bean products |
NAICS | n/a |
SIC | 2034 - Dehydrated Fruits, Vegetables, Soups |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 52,130 |
Annual Production | 19,000,000 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $27,672 | 1,483,880 | kWh | $0.02 |
Electricity Demand | $43,324 | 2,846 | kW-months/year | $15.22 |
Electricity Fees | $156 | - | $ | - |
Natural Gas | $184,777 | 68,366 | MMBtu | $2.70 |
TOTAL ENERGY COSTS | $345,822 | |||
RECOMMENDED SAVINGS* | $77,179 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $77,179 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,360 Cost: $8,400 |
$(-180) | (-9,965) | $(-280) | (-19) | $6,820 | 2,636 | - | - | - | - | - | - |
$(-180) (-9,965) kWh |
$(-280) (-19) kW-months/year |
$6,820 2,636 MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,130 Cost: $1,500 |
- | - | - | - | $2,130 | 823 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,130 823 MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $289 Cost: $288 |
$115 | 6,155 | $174 | 12 | - | - | - | - | - | - | - | - |
$115 6,155 kWh |
$174 12 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $670 Cost: $140 |
- | - | - | - | $670 | 260 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$670 260 MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $380 Cost: $430 |
$150 | 8,499 | $230 | 16 | - | - | - | - | - | - | - | - |
$150 8,499 kWh |
$230 16 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $220 Cost: $290 |
$90 | 4,689 | $130 | 9 | - | - | - | - | - | - | - | - |
$90 4,689 kWh |
$130 9 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS |
Savings: $18,030 Cost: $4,000 |
- | - | - | - | - | - | $18,030 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$18,030 - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $33,500 Cost: $90,000 |
- | - | - | - | - | - | - | - | - | - | $33,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$33,500 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.123 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING |
Savings: $15,600 Cost: $21,000 |
- | - | - | - | - | - | - | - | $15,600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$15,600 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,179 Cost: $126,048 |
$175 | 9,378 | $254 | 18 | $9,620 | 3,719 | $18,030 | - | $15,600 | - | $33,500 | - | $175 9,378 kWh |
$254 18 kW-months/year |
$9,620 3,719 MMBtu |
$18,030 - Tgal |
$15,600 - $ |
$33,500 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $77,179 Cost: $126,048 |
$175 | 9,378 | $254 | 18 | $9,620 | 3,719 | $18,030 | - | $15,600 | - | $33,500 | - | $175 9,378 kWh |
$254 18 kW-months/year |
$9,620 3,719 MMBtu |
$18,030 - Tgal |
$15,600 - $ |
$33,500 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Product | Increase in Production |