Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | injection molded plastic parts |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 66,900 |
Annual Production | 40,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $35,988 | 2,417,644 | kWh | $0.01 |
Electricity Demand | $58,258 | 5,491 | kW-months/year | $10.61 |
Natural Gas | $2,670 | 774 | MMBtu | $3.45 |
TOTAL ENERGY COSTS | $96,916 | |||
RECOMMENDED SAVINGS* | $49,062 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,950 Cost: $4,800 |
$910 | 60,961 | $1,040 | 98 | - | - | - | - | - | - | - | - |
$910 60,961 kWh |
$1,040 98 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $62 Cost: $150 |
$29 | 2,052 | $33 | 3 | - | - | - | - | - | - | - | - |
$29 2,052 kWh |
$33 3 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $350 Cost: $270 |
$160 | 11,137 | $190 | 18 | - | - | - | - | - | - | - | - |
$160 11,137 kWh |
$190 18 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $590 Cost: $1,260 |
- | - | - | - | $590 | 180 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$590 180 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $28,480 Cost: $800 |
- | - | - | - | - | - | - | - | - | - | $28,480 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
$28,480 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.623 EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME |
Savings: $11,810 Cost: $29,000 |
$(-40) | (-2,931) | $(-50) | (-5) | - | - | - | - | $11,900 | - | - | - |
$(-40) (-2,931) kWh |
$(-50) (-5) kW-months/year |
- - lb |
- - $ |
$11,900 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $5,820 Cost: $18,800 |
- | - | - | - | - | - | $5,820 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$5,820 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,062 Cost: $55,080 |
$1,059 | 71,219 | $1,213 | 114 | $590 | 180 | $5,820 | - | $11,900 | - | $28,480 | - | $1,059 71,219 kWh |
$1,213 114 kW-months/year |
$590 180 lb |
$5,820 - $ |
$11,900 - $ |
$28,480 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Primary Product |