Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | commercial printing |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $5,000,000-$10,000,000 |
# of Employees | 68 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 1,500,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,180 | 1,058,910 | kWh | $0.02 |
Electricity Demand | $53,354 | 3,745 | kW-months/year | $14.25 |
Electricity Fees | $293 | - | $ | - |
Natural Gas | $17,176 | 4,531 | MMBtu | $3.79 |
TOTAL ENERGY COSTS | $86,203 | |||
RECOMMENDED SAVINGS* | $65,365 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $780 Cost: - |
$780 | 43,376 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$780 43,376 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $165 Cost: $96 |
$76 | 4,103 | $89 | 6 | - | - | - | - | - | - | - | - | - | - | - | - |
$76 4,103 kWh |
$89 6 kW-months/year |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $17,160 Cost: - |
- | - | - | - | $1,440 | 495 | - | - | - | - | - | - | $15,720 | - | - | - |
- - kWh |
- - kW-months/year |
$1,440 495 gal |
- - lb |
- - lb |
- - $ |
$15,720 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $12,780 Cost: $1,800 |
- | - | - | - | - | - | $12,780 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$12,780 - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $480 Cost: - |
- | - | - | - | - | - | - | - | $480 | 120 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$480 120 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $34,000 Cost: $12,680 |
- | - | - | - | - | - | - | - | - | - | $(-50,000) | - | - | - | $84,000 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
- - lb |
$(-50,000) - $ |
- - $ |
$84,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $65,365 Cost: $14,576 |
$856 | 47,479 | $89 | 6 | $1,440 | 495 | $12,780 | - | $480 | 120 | $(-50,000) | - | $15,720 | - | $84,000 | - | $856 47,479 kWh |
$89 6 kW-months/year |
$1,440 495 gal |
$12,780 - lb |
$480 120 lb |
$(-50,000) - $ |
$15,720 - $ |
$84,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - gal |
- - lb |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product |