Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | wood display cabinets & fixtures |
NAICS | n/a |
SIC | 2541 - Wood Partitions And Fixtures |
Sales | $5,000,000-$10,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 2,000 Pieces |
Production Hrs. Annual | 5,720 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,184 | 1,103,458 | kWh | $0.02 |
Electricity Demand | $46,747 | 3,494 | kW-months/year | $13.38 |
Electricity Fees | $216 | - | $ | - |
Natural Gas | $12,176 | 3,375 | MMBtu | $3.61 |
TOTAL ENERGY COSTS | $80,123 | |||
RECOMMENDED SAVINGS* | $49,825 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $635 Cost: $995 |
$147 | 8,499 | $488 | 36 | - | - | - | - | - | - | - | - |
$147 8,499 kWh |
$488 36 kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,200 Cost: $2,920 |
$1,200 | 69,461 | - | - | - | - | - | - | - | - | - | - |
$1,200 69,461 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER |
Savings: $1,180 Cost: $1,000 |
- | - | - | - | - | - | $910 | - | $270 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$910 - $ |
$270 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $930 Cost: - |
- | - | - | - | $760 | 70 | - | - | $170 | - | - | - |
- - kWh |
- - kW-months/year |
$760 70 lb |
- - $ |
$170 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $970 Cost: - |
- | - | - | - | - | - | - | - | $970 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$970 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $360 Cost: - |
- | - | - | - | $360 | 80 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$360 80 lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.451 ADD ADDITIONAL PRODUCTION SHIFT |
Savings: $35,580 Cost: $730 |
$(-190) | (-10,844) | - | - | - | - | $(-2,990) | - | - | - | $38,760 | - |
$(-190) (-10,844) kWh |
- - kW-months/year |
- - lb |
$(-2,990) - $ |
- - $ |
$38,760 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $8,970 Cost: $20,000 |
- | - | - | - | - | - | $8,970 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$8,970 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,825 Cost: $25,645 |
$1,157 | 67,116 | $488 | 36 | $1,120 | 150 | $6,890 | - | $1,410 | - | $38,760 | - | $1,157 67,116 kWh |
$488 36 kW-months/year |
$1,120 150 lb |
$6,890 - $ |
$1,410 - $ |
$38,760 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Primary Product |