Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1998 |
Principal Product | printed circuit boards |
NAICS | n/a |
SIC | 3672 - Printed Circuit Boards |
Sales | $1,000,000-$5,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 17,520 |
Annual Production | 46,940 Thousand Feet |
Production Hrs. Annual | 4,420 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,724 | 1,144,490 | kWh | $0.02 |
Electricity Demand | $44,061 | 3,133 | kW-months/year | $14.06 |
Electricity Fees | $204 | - | $ | - |
Natural Gas | $4,863 | 1,113 | MMBtu | $4.37 |
TOTAL ENERGY COSTS | $85,873 | |||
RECOMMENDED SAVINGS* | $28,440 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,590 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $850 Cost: $1,000 |
- | - | $850 | 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$850 60 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $140 Cost: $420 |
- | - | - | - | $140 | 34 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$140 34 MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4151 MINIMIZE WATER USAGE |
Savings: $9,100 Cost: $11,210 |
- | - | - | - | - | - | $3,040 | 2,114,000 | - | - | - | - | $2,000 | - | - | - | $4,060 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,040 2,114,000 Tgal |
- - gal |
- - $ |
$2,000 - $ |
- - $ |
$4,060 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1293 SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE |
Savings: $8,870 Cost: $2,500 |
$(-40) | (-2,052) | - | - | - | - | - | - | - | - | - | - | - | - | $8,910 | - | - | - |
$(-40) (-2,052) kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
$8,910 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1242 ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT |
Savings: $4,550 Cost: $2,000 |
$146 | 7,913 | - | - | - | - | - | - | - | - | - | - | - | - | $4,404 | - | - | - |
$146 7,913 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
$4,404 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1293 SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE |
Savings: $2,580 Cost: $25,000 |
$(-430) | (-23,447) | - | - | - | - | - | - | $760 | 234 | $650 | - | - | - | $1,600 | - | - | - |
$(-430) (-23,447) kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$760 234 gal |
$650 - $ |
- - $ |
$1,600 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS |
Savings: $2,350 Cost: $6,900 |
$(-140) | (-7,913) | - | - | - | - | - | - | $2,490 | 780 | - | - | - | - | - | - | - | - |
$(-140) (-7,913) kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$2,490 780 gal |
- - $ |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,440 Cost: $49,030 |
$(-464) | (-25,499) | $850 | 60 | $140 | 34 | $3,040 | 2,114,000 | $3,250 | 1,014 | $650 | - | $2,000 | - | $14,914 | - | $4,060 | - | $(-464) (-25,499) kWh |
$850 60 kW-months/year |
$140 34 MMBtu |
$3,040 2,114,000 Tgal |
$3,250 1,014 gal |
$650 - $ |
$2,000 - $ |
$14,914 - $ |
$4,060 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,590 Cost: $48,030 |
$(-464) | (-25,499) | - | - | $140 | 34 | $3,040 | 2,114,000 | $3,250 | 1,014 | $650 | - | $2,000 | - | $14,914 | - | $4,060 | - | $(-464) (-25,499) kWh |
- - kW-months/year |
$140 34 MMBtu |
$3,040 2,114,000 Tgal |
$3,250 1,014 gal |
$650 - $ |
$2,000 - $ |
$14,914 - $ |
$4,060 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Water Consumption |