Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2001 |
Principal Product | Surgical and medical instruments and apparatus |
NAICS | n/a |
SIC | 3841 - Surgical And Medical Instruments |
Sales | $1,000,000-$5,000,000 |
# of Employees | 450 |
Plant Area (Sq.Ft.) | 225,000 |
Annual Production | 3,082,500 Pieces |
Production Hrs. Annual | 6,760 |
Location (State) | NM |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $364,240 | 9,080,400 | kWh | $0.04 |
Electricity Demand | $117,012 | 1,342 | kW-months/year | $87.19 |
Electricity Fees | $69,480 | - | $ | - |
Natural Gas | $91,500 | 13,030 | MMBtu | $7.02 |
TOTAL ENERGY COSTS | $674,692 | |||
RECOMMENDED SAVINGS* | $40,090 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,070 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,910 Cost: $3,000 |
$4,220 | 106,600 | $1,690 | 146 | - | - | - | - |
$4,220 106,600 kWh |
$1,690 146 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $5,300 Cost: $6,000 |
- | - | $5,300 | 458 | - | - | - | - |
- - kWh |
$5,300 458 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,660 Cost: $2,200 |
$1,190 | 30,000 | $470 | 41 | - | - | - | - |
$1,190 30,000 kWh |
$470 41 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,650 Cost: - |
$1,650 | 41,800 | - | - | - | - | - | - |
$1,650 41,800 kWh |
- - kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $900 Cost: - |
$650 | 16,400 | $250 | 22 | - | - | - | - |
$650 16,400 kWh |
$250 22 kW-months/year |
- - gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8228 REPLACE HEAVY METAL REAGENTS WITH NON-HAZARDOUS REAGENTS |
Savings: $21,060 Cost: $14,000 |
- | - | - | - | $21,060 | 15,600 | - | - |
- - kWh |
- - kW-months/year |
$21,060 15,600 gal |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2141 USE CYLINDRICAL TANKS WITH HEIGHT TO DIAMETER RATIOS CLOSE TO ONE TO REDUCE WETTED SURFACE |
Savings: $3,610 Cost: $180 |
- | - | - | - | - | - | $3,610 | 5,530 |
- - kWh |
- - kW-months/year |
- - gal |
$3,610 5,530 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,090 Cost: $25,380 |
$7,710 | 194,800 | $7,710 | 667 | $21,060 | 15,600 | $3,610 | 5,530 | $7,710 194,800 kWh |
$7,710 667 kW-months/year |
$21,060 15,600 gal |
$3,610 5,530 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,070 Cost: $3,180 |
$6,520 | 164,800 | $1,940 | 168 | - | - | $3,610 | 5,530 | $6,520 164,800 kWh |
$1,940 168 kW-months/year |
- - gal |
$3,610 5,530 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) |