Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2001
Principal Product Surgical and medical instruments and apparatus
NAICS n/a
SIC 3841 - Surgical And Medical Instruments
Sales $1,000,000-$5,000,000
# of Employees 450
Plant Area (Sq.Ft.) 225,000
Annual Production 3,082,500 Pieces
Production Hrs. Annual 6,760
Location (State) NM
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $364,240 9,080,400 kWh $0.04
Electricity Demand $117,012 1,342 kW-months/year $87.19
Electricity Fees $69,480 - $ -
Natural Gas $91,500 13,030 MMBtu $7.02
TOTAL ENERGY COSTS $674,692
RECOMMENDED SAVINGS* $40,090 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,070
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz)
$ kWh $ kW-months/year $ gal $ lb
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$5,910
Cost:
$3,000
$4,220 106,600 $1,690 146 - - - - $4,220
106,600
kWh
$1,690
146
kW-months/year
-
-
gal
-
-
lb
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$5,300
Cost:
$6,000
- - $5,300 458 - - - - -
-
kWh
$5,300
458
kW-months/year
-
-
gal
-
-
lb
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,660
Cost:
$2,200
$1,190 30,000 $470 41 - - - - $1,190
30,000
kWh
$470
41
kW-months/year
-
-
gal
-
-
lb
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,650
Cost:
-
$1,650 41,800 - - - - - - $1,650
41,800
kWh
-
-
kW-months/year
-
-
gal
-
-
lb
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$900
Cost:
-
$650 16,400 $250 22 - - - - $650
16,400
kWh
$250
22
kW-months/year
-
-
gal
-
-
lb
06: 3.8228 REPLACE HEAVY METAL REAGENTS WITH NON-HAZARDOUS REAGENTS Savings:
$21,060
Cost:
$14,000
- - - - $21,060 15,600 - - -
-
kWh
-
-
kW-months/year
$21,060
15,600
gal
-
-
lb
07: 3.2141 USE CYLINDRICAL TANKS WITH HEIGHT TO DIAMETER RATIOS CLOSE TO ONE TO REDUCE WETTED SURFACE Savings:
$3,610
Cost:
$180
- - - - - - $3,610 5,530 -
-
kWh
-
-
kW-months/year
-
-
gal
$3,610
5,530
lb
TOTAL RECOMMENDED Savings:
$40,090
Cost:
$25,380
$7,710 194,800 $7,710 667 $21,060 15,600 $3,610 5,530 $7,710
194,800
kWh
$7,710
667
kW-months/year
$21,060
15,600
gal
$3,610
5,530
lb
TOTAL IMPLEMENTED Savings:
$12,070
Cost:
$3,180
$6,520 164,800 $1,940 168 - - $3,610 5,530 $6,520
164,800
kWh
$1,940
168
kW-months/year
-
-
gal
$3,610
5,530
lb
Savings
Cost
$ kWh $ kW-months/year $ gal $ lb
Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz) Electricity Usage Electricity Demand Other Liquid (haz) Solid Waste (non-haz)