Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2001 |
Principal Product | Desiccants |
NAICS | n/a |
SIC | 3295 - Minerals, Ground Or Treated |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 147,000 |
Annual Production | 810,000,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NM |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $280,871 | 5,519,176 | kWh | $0.05 |
Electricity Demand | $54,076 | 1,054 | kW-months/year | $51.31 |
Electricity Fees | $80,618 | - | $ | - |
Natural Gas | $203,653 | 32,319 | MMBtu | $6.30 |
TOTAL ENERGY COSTS | $687,438 | |||
RECOMMENDED SAVINGS* | $41,240 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,590 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,730 Cost: $35,830 |
$6,640 | 95,800 | $1,090 | 184 | - | - | - | - | - | - | - | - | - | - | - | - |
$6,640 95,800 kWh |
$1,090 184 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,010 Cost: $1,600 |
$6,190 | 100,500 | $820 | 138 | - | - | - | - | - | - | - | - | - | - | - | - |
$6,190 100,500 kWh |
$820 138 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,780 Cost: $1,760 |
$600 | 6,200 | $80 | 14 | $2,100 | 333 | - | - | - | - | - | - | - | - | - | - |
$600 6,200 kWh |
$80 14 kW-months/year |
$2,100 333 MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,500 Cost: $630 |
- | - | - | - | $1,500 | 238 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,500 238 MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,290 Cost: - |
$2,520 | 47,500 | $720 | 80 | - | - | - | - | - | - | $(-330) | - | $(-1,620) | - | - | - |
$2,520 47,500 kWh |
$720 80 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
$(-330) - $ |
$(-1,620) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $1,130 Cost: $2,170 |
- | - | - | - | $1,130 | 179 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,130 179 MMBtu |
- - Tgal |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $15,440 Cost: - |
- | - | - | - | - | - | $3,890 | - | - | - | - | - | - | - | $11,550 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,890 - Tgal |
- - gal |
- - $ |
- - $ |
$11,550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $4,360 Cost: $4,000 |
$(-210) | (-5,300) | $(-90) | (-7) | - | - | - | - | $5,940 | 648 | - | - | $(-1,280) | - | - | - |
$(-210) (-5,300) kWh |
$(-90) (-7) kW-months/year |
- - MMBtu |
- - Tgal |
$5,940 648 gal |
- - $ |
$(-1,280) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,240 Cost: $45,990 |
$15,740 | 244,700 | $2,620 | 409 | $4,730 | 750 | $3,890 | - | $5,940 | 648 | $(-330) | - | $(-2,900) | - | $11,550 | - | $15,740 244,700 kWh |
$2,620 409 kW-months/year |
$4,730 750 MMBtu |
$3,890 - Tgal |
$5,940 648 gal |
$(-330) - $ |
$(-2,900) - $ |
$11,550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,590 Cost: $4,630 |
$2,310 | 42,200 | $630 | 73 | $1,500 | 238 | $3,890 | - | $5,940 | 648 | $(-330) | - | $(-2,900) | - | $11,550 | - | $2,310 42,200 kWh |
$630 73 kW-months/year |
$1,500 238 MMBtu |
$3,890 - Tgal |
$5,940 648 gal |
$(-330) - $ |
$(-2,900) - $ |
$11,550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | By-product Production |