Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2003 |
Principal Product | Commercial printing (phone books) |
NAICS | 511140 - Directory and Mailing List Publishers |
SIC | 2741 - Miscellaneous Publishing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 30,600,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $347,373 | 13,371,000 | kWh | $0.03 |
Electricity Demand | $191,416 | 25,728 | kW-months/year | $7.44 |
Electricity Fees | $420 | - | $ | - |
Natural Gas | $20,574 | 5,163 | MMBtu | $3.98 |
TOTAL ENERGY COSTS | $566,538 | |||
RECOMMENDED SAVINGS* | $4,119,590 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,560 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $13,370 Cost: $10,000 |
$9,520 | 365,500 | $3,850 | 518 | - | - | - | - | - | - |
$9,520 365,500 kWh |
$3,850 518 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,370 Cost: $230 |
$5,300 | 203,200 | $2,070 | 278 | - | - | - | - | - | - |
$5,300 203,200 kWh |
$2,070 278 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,940 Cost: $280 |
$2,940 | 112,700 | - | - | - | - | - | - | - | - |
$2,940 112,700 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,070 Cost: $7,760 |
$1,320 | 50,700 | $750 | 101 | - | - | - | - | - | - |
$1,320 50,700 kWh |
$750 101 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,830 Cost: $4,140 |
$1,410 | 54,000 | - | - | $110 | - | $310 | - | - | - |
$1,410 54,000 kWh |
- - kW-months/year |
$110 - $ |
$310 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,810 Cost: $1,250 |
$1,230 | 47,200 | $580 | 78 | - | - | - | - | - | - |
$1,230 47,200 kWh |
$580 78 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $1,200 Cost: $570 |
$760 | 29,000 | $300 | 40 | $50 | - | $90 | - | - | - |
$760 29,000 kWh |
$300 40 kW-months/year |
$50 - $ |
$90 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $4,089,000 Cost: $4,200,000 |
- | - | - | - | - | - | - | - | $4,089,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$4,089,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $4,119,590 Cost: $4,224,230 |
$22,480 | 862,300 | $7,550 | 1,015 | $160 | - | $400 | - | $4,089,000 | - | $22,480 862,300 kWh |
$7,550 1,015 kW-months/year |
$160 - $ |
$400 - $ |
$4,089,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,560 Cost: $19,520 |
$20,310 | 779,300 | $7,250 | 975 | - | - | - | - | - | - | $20,310 779,300 kWh |
$7,250 975 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production |