Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2003 |
Principal Product | Finished household furniture |
NAICS | 337122 - Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511 - Wood Household Furniture |
Sales | $5,000,000-$10,000,000 |
# of Employees | 72 |
Plant Area (Sq.Ft.) | 36,000 |
Annual Production | 822 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | MT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,699 | 1,230,800 | kWh | $0.04 |
Electricity Demand | $23,157 | 2,883 | kW-months/year | $8.03 |
Electricity Fees | $96 | - | $ | - |
Natural Gas | $19,142 | 3,676 | MMBtu | $5.21 |
TOTAL ENERGY COSTS | $93,094 | |||
RECOMMENDED SAVINGS* | $71,989 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,530 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,720 Cost: $16,720 |
$5,870 | 123,000 | $1,900 | 237 | - | - | $(-1,050) | - | - | - |
$5,870 123,000 kWh |
$1,900 237 kW-months/year |
- - MMBtu |
$(-1,050) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,530 Cost: $1,050 |
$3,420 | 71,700 | $1,110 | 138 | - | - | - | - | - | - |
$3,420 71,700 kWh |
$1,110 138 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR |
Savings: $3,380 Cost: $8,630 |
$(-420) | (-8,700) | $(-140) | (-17) | $3,940 | 526 | - | - | - | - |
$(-420) (-8,700) kWh |
$(-140) (-17) kW-months/year |
$3,940 526 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $3,310 Cost: $870 |
$3,310 | 69,300 | - | - | - | - | - | - | - | - |
$3,310 69,300 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,750 Cost: $1,410 |
- | - | - | - | $2,750 | 368 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,750 368 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,299 Cost: $132 |
$983 | 20,592 | $316 | 39 | - | - | - | - | - | - |
$983 20,592 kWh |
$316 39 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $50,000 Cost: $301,060 |
- | - | - | - | - | - | - | - | $50,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$50,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,989 Cost: $329,872 |
$13,163 | 275,892 | $3,186 | 397 | $6,690 | 894 | $(-1,050) | - | $50,000 | - | $13,163 275,892 kWh |
$3,186 397 kW-months/year |
$6,690 894 MMBtu |
$(-1,050) - $ |
$50,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,530 Cost: $1,050 |
$3,420 | 71,700 | $1,110 | 138 | - | - | - | - | - | - | $3,420 71,700 kWh |
$1,110 138 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Increase in Production |