Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2004 |
Principal Product | Kitchen and bath cabinets |
NAICS | 337110 - Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434 - Wood Kitchen Cabinets |
Sales | $5,000,000-$10,000,000 |
# of Employees | 89 |
Plant Area (Sq.Ft.) | 42,000 |
Annual Production | 15,000 Pieces |
Production Hrs. Annual | 2,912 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,354 | 644,480 | kWh | $0.03 |
Electricity Demand | $38,457 | 2,837 | kW-months/year | $13.56 |
Electricity Fees | $396 | - | $ | - |
Natural Gas | $22,435 | 3,186 | MMBtu | $7.04 |
TOTAL ENERGY COSTS | $88,662 | |||
RECOMMENDED SAVINGS* | $36,016 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,886 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.8125 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER |
Savings: $16,080 Cost: $1,150 |
- | - | - | - | $4,210 | 2,013 | $2,510 | - | - | - | $9,360 | - |
- - kWh |
- - kW-months/year |
$4,210 2,013 gal |
$2,510 - $ |
- - $ |
$9,360 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $14,440 Cost: $12,420 |
- | - | $(-270) | (-20) | $4,000 | 2,852 | $(-1,440) | - | - | - | $12,150 | - |
- - kWh |
$(-270) (-20) kW-months/year |
$4,000 2,852 gal |
$(-1,440) - $ |
- - $ |
$12,150 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,940 Cost: $360 |
$1,170 | 37,900 | $1,770 | 128 | - | - | - | - | - | - | - | - |
$1,170 37,900 kWh |
$1,770 128 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,330 Cost: $60 |
$530 | 17,200 | $800 | 58 | - | - | - | - | - | - | - | - |
$530 17,200 kWh |
$800 58 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $130 Cost: $340 |
$50 | 1,700 | $80 | 6 | - | - | - | - | - | - | - | - |
$50 1,700 kWh |
$80 6 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $960 Cost: $500 |
- | - | - | - | - | - | - | - | $960 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
- - $ |
$960 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $136 Cost: $70 |
$55 | 1,840 | $99 | 7 | - | - | - | - | - | - | $(-18) | - |
$55 1,840 kWh |
$99 7 kW-months/year |
- - gal |
- - $ |
- - $ |
$(-18) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,016 Cost: $14,900 |
$1,805 | 58,640 | $2,479 | 179 | $8,210 | 4,865 | $1,070 | - | $960 | - | $21,492 | - | $1,805 58,640 kWh |
$2,479 179 kW-months/year |
$8,210 4,865 gal |
$1,070 - $ |
$960 - $ |
$21,492 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,886 Cost: $14,560 |
$1,755 | 56,940 | $2,399 | 173 | $8,210 | 4,865 | $1,070 | - | $960 | - | $21,492 | - | $1,755 56,940 kWh |
$2,399 173 kW-months/year |
$8,210 4,865 gal |
$1,070 - $ |
$960 - $ |
$21,492 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |