Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2005 |
Principal Product | Aircraft |
NAICS | 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 7 Pieces |
Production Hrs. Annual | 6,916 |
Location (State) | NM |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $115,357 | 1,752,960 | kWh | $0.07 |
Electricity Demand | $11,817 | 3,540 | kW-months/year | $3.34 |
Electricity Fees | $2,392 | - | $ | - |
Natural Gas | $6,747 | 775 | MMBtu | $8.71 |
TOTAL ENERGY COSTS | $136,313 | |||
RECOMMENDED SAVINGS* | $19,950 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7145 INSTALL SKYLIGHTS |
Savings: $9,660 Cost: $40,800 |
$7,150 | 175,500 | $1,530 | 367 | - | - | $870 | - | $110 | - |
$7,150 175,500 kWh |
$1,530 367 kW-months/year |
- - MMBtu |
$870 - $ |
$110 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,460 Cost: $7,700 |
$2,790 | 68,500 | $390 | 94 | - | - | $140 | - | $140 | - |
$2,790 68,500 kWh |
$390 94 kW-months/year |
- - MMBtu |
$140 - $ |
$140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9111 USE SOLAR HEAT TO HEAT MAKE-UP AIR |
Savings: $2,480 Cost: $30,770 |
$(-310) | (-7,600) | $(-80) | (-18) | $2,870 | 357 | - | - | - | - |
$(-310) (-7,600) kWh |
$(-80) (-18) kW-months/year |
$2,870 357 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,420 Cost: $7,570 |
$1,640 | 40,200 | - | - | - | - | $80 | - | $700 | - |
$1,640 40,200 kWh |
- - kW-months/year |
- - MMBtu |
$80 - $ |
$700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,370 Cost: $1,000 |
$(-200) | (-4,900) | $(-30) | (-7) | $1,600 | 199 | - | - | - | - |
$(-200) (-4,900) kWh |
$(-30) (-7) kW-months/year |
$1,600 199 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $560 Cost: $1,760 |
$560 | 13,800 | - | - | - | - | - | - | - | - |
$560 13,800 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,950 Cost: $89,600 |
$11,630 | 285,500 | $1,810 | 436 | $4,470 | 556 | $1,090 | - | $950 | - | $11,630 285,500 kWh |
$1,810 436 kW-months/year |
$4,470 556 MMBtu |
$1,090 - $ |
$950 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |