Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2006 |
Principal Product | Robotic welders |
NAICS | 333992 - Welding and Soldering Equipment Manufacturing |
SIC | 3548 - Welding Apparatus |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 107,250 |
Annual Production | 50 Pieces |
Production Hrs. Annual | 3,120 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $46,624 | 2,455,200 | kWh | $0.02 |
Electricity Demand | $74,699 | 8,691 | kW-months/year | $8.59 |
Electricity Fees | $324 | - | $ | - |
Natural Gas | $10,231 | 9,495 | MMBtu | $1.08 |
TOTAL ENERGY COSTS | $131,878 | |||
RECOMMENDED SAVINGS* | $24,360 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $210 Cost: - |
$210 | 10,800 | - | - | - | - | - | - | - | - |
$210 10,800 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,220 Cost: $31,750 |
$4,490 | 236,100 | $11,010 | 1,263 | - | - | $440 | - | $280 | - |
$4,490 236,100 kWh |
$11,010 1,263 kW-months/year |
- - MMBtu |
$440 - $ |
$280 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9111 USE SOLAR HEAT TO HEAT MAKE-UP AIR |
Savings: $3,480 Cost: $21,810 |
- | - | - | - | $3,480 | 369 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,480 369 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $2,130 Cost: $16,160 |
- | - | - | - | $2,130 | 226 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,130 226 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,500 Cost: $2,950 |
$270 | 14,100 | $1,230 | 170 | - | - | - | - | - | - |
$270 14,100 kWh |
$1,230 170 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $820 Cost: $740 |
$80 | 4,100 | $110 | 12 | - | - | $140 | - | $490 | - |
$80 4,100 kWh |
$110 12 kW-months/year |
- - MMBtu |
$140 - $ |
$490 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $24,360 Cost: $73,410 |
$5,050 | 265,100 | $12,350 | 1,445 | $5,610 | 595 | $580 | - | $770 | - | $5,050 265,100 kWh |
$12,350 1,445 kW-months/year |
$5,610 595 MMBtu |
$580 - $ |
$770 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,220 Cost: $31,750 |
$4,490 | 236,100 | $11,010 | 1,263 | - | - | $440 | - | $280 | - | $4,490 236,100 kWh |
$11,010 1,263 kW-months/year |
- - MMBtu |
$440 - $ |
$280 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |