IAC logo
IAC Assessment: CO0609
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0609
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2007
Principal Product Packaged teas
NAICS 311999 - All Other Miscellaneous Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $100,000,000-$500,000,000
# of Employees 220
Plant Area (Sq.Ft.) 155,000
Annual Production 5,800,000 Pieces
Production Hrs. Annual 6,240
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $132,886 3,936,000 kWh $0.03
Electricity Demand $149,878 9,389 kW-months/year $15.96
Electricity Fees $2,062 - $ -
Natural Gas $30,729 3,671 MMBtu $8.37
TOTAL ENERGY COSTS $315,555
RECOMMENDED SAVINGS* $9,071 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,331
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,170
Cost:
$300
$1,850 55,500 $2,320 138 - - - - $1,850
55,500
kWh
$2,320
138
kW-months/year
-
-
$
-
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,370
Cost:
$60
$750 22,600 $620 37 - - - - $750
22,600
kWh
$620
37
kW-months/year
-
-
$
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$161
Cost:
$846
$79 2,380 $82 5 - - - - $79
2,380
kWh
$82
5
kW-months/year
-
-
$
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$580
Cost:
$4,570
$290 8,800 $290 17 - - - - $290
8,800
kWh
$290
17
kW-months/year
-
-
$
-
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$1,530
Cost:
$11,000
$490 14,600 $1,040 62 - - - - $490
14,600
kWh
$1,040
62
kW-months/year
-
-
$
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,260
Cost:
$2,160
$760 22,900 $370 22 $40 - $90 - $760
22,900
kWh
$370
22
kW-months/year
$40
-
$
$90
-
$
TOTAL RECOMMENDED Savings:
$9,071
Cost:
$18,936
$4,219 126,780 $4,722 281 $40 - $90 - $4,219
126,780
kWh
$4,722
281
kW-months/year
$40
-
$
$90
-
$
TOTAL IMPLEMENTED Savings:
$4,331
Cost:
$1,146
$1,929 57,880 $2,402 143 - - - - $1,929
57,880
kWh
$2,402
143
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost