Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2009 |
Principal Product | Metal lockers |
NAICS | 337215 - Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2542 - Partitions And Fixtures, Except Wood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 34,000 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $183,856 | 2,067,800 | kWh | $0.09 |
Electricity Demand | $35,658 | 5,943 | kW-months/year | $6.00 |
Natural Gas | $159,866 | 14,565 | MMBtu | $10.98 |
TOTAL ENERGY COSTS | $379,380 | |||
RECOMMENDED SAVINGS* | $33,100 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,020 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,830 Cost: $890 |
$7,380 | 83,800 | $1,450 | 242 | - | - | - | - | - | - |
$7,380 83,800 kWh |
$1,450 242 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,050 Cost: $1,730 |
- | - | - | - | $6,050 | 593 | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,050 593 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,010 Cost: $110 |
$840 | 9,500 | $170 | 28 | - | - | - | - | - | - |
$840 9,500 kWh |
$170 28 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,150 Cost: $4,590 |
$4,980 | 56,500 | $980 | 163 | - | - | $(-30) | - | $220 | - |
$4,980 56,500 kWh |
$980 163 kW-months/year |
- - MMBtu |
$(-30) - $ |
$220 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,160 Cost: $21,150 |
$3,410 | 38,700 | $670 | 112 | - | - | - | - | $80 | - |
$3,410 38,700 kWh |
$670 112 kW-months/year |
- - MMBtu |
- - $ |
$80 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,830 Cost: $12,240 |
$2,670 | 30,300 | $750 | 126 | - | - | $20 | - | $390 | - |
$2,670 30,300 kWh |
$750 126 kW-months/year |
- - MMBtu |
$20 - $ |
$390 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,920 Cost: $210 |
$1,820 | 20,700 | - | - | - | - | $40 | - | $60 | - |
$1,820 20,700 kWh |
- - kW-months/year |
- - MMBtu |
$40 - $ |
$60 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,150 Cost: $1,360 |
$1,080 | 12,300 | - | - | - | - | $30 | - | $40 | - |
$1,080 12,300 kWh |
- - kW-months/year |
- - MMBtu |
$30 - $ |
$40 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,100 Cost: $42,280 |
$22,180 | 251,800 | $4,020 | 671 | $6,050 | 593 | $60 | - | $790 | - | $22,180 251,800 kWh |
$4,020 671 kW-months/year |
$6,050 593 MMBtu |
$60 - $ |
$790 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,020 Cost: $40,600 |
$18,440 | 209,300 | $3,850 | 643 | $6,050 | 593 | $(-10) | - | $690 | - | $18,440 209,300 kWh |
$3,850 643 kW-months/year |
$6,050 593 MMBtu |
$(-10) - $ |
$690 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |