IAC logo
IAC Assessment: CO0639
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0639
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2010
Principal Product Fabricated steel
NAICS 332312 - Fabricated Structural Metal Manufacturing
SIC 3441 - Fabricated Structural Metal
Sales $10,000,000-$50,000,000
# of Employees 35
Plant Area (Sq.Ft.) 62,100
Annual Production 2,000,000 Pounds
Production Hrs. Annual 2,080
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $22,742 567,520 kWh $0.04
Electricity Demand $60,507 3,674 kW-months/year $16.47
Electricity Fees $2,161 - $ -
Natural Gas $15,900 2,070 MMBtu $7.68
TOTAL ENERGY COSTS $101,310
RECOMMENDED SAVINGS* $17,640 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,180
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,180
Cost:
$340
$630 12,900 $1,550 74 - - - - $630
12,900
kWh
$1,550
74
kW-months/year
-
-
$
-
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$1,600
Cost:
$10,320
$460 9,500 $1,140 55 - - - - $460
9,500
kWh
$1,140
55
kW-months/year
-
-
$
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,040
Cost:
$13,990
$340 7,000 $1,700 82 - - - - $340
7,000
kWh
$1,700
82
kW-months/year
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,710
Cost:
$33,800
$3,170 65,000 $5,630 271 $(-430) - $340 - $3,170
65,000
kWh
$5,630
271
kW-months/year
$(-430)
-
$
$340
-
$
05: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$1,060
Cost:
$3,620
$210 4,300 $810 39 $30 - $10 - $210
4,300
kWh
$810
39
kW-months/year
$30
-
$
$10
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$2,050
Cost:
$35,000
$760 15,600 $1,290 62 - - - - $760
15,600
kWh
$1,290
62
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$17,640
Cost:
$97,070
$5,570 114,300 $12,120 583 $(-400) - $350 - $5,570
114,300
kWh
$12,120
583
kW-months/year
$(-400)
-
$
$350
-
$
TOTAL IMPLEMENTED Savings:
$2,180
Cost:
$340
$630 12,900 $1,550 74 - - - - $630
12,900
kWh
$1,550
74
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost