Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2010 |
Principal Product | Plastic Bags |
NAICS | 322220 - Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2673 - Bags: Plastics, Laminated, & Coated |
Sales | $10,000,000-$50,000,000 |
# of Employees | 68 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 14,400,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $201,266 | 5,366,000 | kWh | $0.04 |
Electricity Demand | $130,333 | 8,550 | kW-months/year | $15.24 |
Electricity Fees | $1,752 | - | $ | - |
Natural Gas | $24,636 | 3,738 | MMBtu | $6.59 |
TOTAL ENERGY COSTS | $357,987 | |||
RECOMMENDED SAVINGS* | $45,650 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,960 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,720 Cost: $1,140 |
$7,400 | 161,400 | $4,320 | 221 | - | - | - | - |
$7,400 161,400 kWh |
$4,320 221 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $8,870 Cost: $3,410 |
$4,990 | 108,800 | $3,880 | 199 | - | - | - | - |
$4,990 108,800 kWh |
$3,880 199 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,900 Cost: $2,650 |
$2,160 | 47,200 | $1,740 | 89 | - | - | - | - |
$2,160 47,200 kWh |
$1,740 89 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,710 Cost: $18,500 |
$11,920 | 260,100 | $6,940 | 356 | $130 | - | $(-280) | - |
$11,920 260,100 kWh |
$6,940 356 kW-months/year |
$130 - $ |
$(-280) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,920 Cost: $35,000 |
$710 | 15,600 | $1,210 | 62 | - | - | - | - |
$710 15,600 kWh |
$1,210 62 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $530 Cost: $3,060 |
$350 | 7,700 | $210 | 11 | $20 | - | $(-50) | - |
$350 7,700 kWh |
$210 11 kW-months/year |
$20 - $ |
$(-50) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,650 Cost: $63,760 |
$27,530 | 600,800 | $18,300 | 938 | $150 | - | $(-330) | - | $27,530 600,800 kWh |
$18,300 938 kW-months/year |
$150 - $ |
$(-330) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,960 Cost: $22,700 |
$19,670 | 429,200 | $11,470 | 588 | $150 | - | $(-330) | - | $19,670 429,200 kWh |
$11,470 588 kW-months/year |
$150 - $ |
$(-330) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |