Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2011
Principal Product Lumber
NAICS 321113 - Sawmills
SIC 2421 - Sawmills And Planing Mills, General
Sales $1,000,000-$5,000,000
# of Employees 30
Plant Area (Sq.Ft.) 24,500
Annual Production 3,000,000 Pieces
Production Hrs. Annual 1,872
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $12,904 346,880 kWh $0.04
Electricity Demand $57,436 3,008 kW-months/year $19.09
Electricity Fees $483 - $ -
Fuel Oil #2 $113,120 4,200 MMBtu $26.93
TOTAL ENERGY COSTS $183,943
RECOMMENDED SAVINGS* $7,890 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,440
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,240
Cost:
$5,950
$120 3,000 $1,120 58 - - $120
3,000
kWh
$1,120
58
kW-months/year
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,490
Cost:
$520
$590 15,400 $1,900 98 - - $590
15,400
kWh
$1,900
98
kW-months/year
-
-
$
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$950
Cost:
$600
$100 2,700 $850 44 - - $100
2,700
kWh
$850
44
kW-months/year
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$790
Cost:
$1,410
$80 2,100 $710 37 - - $80
2,100
kWh
$710
37
kW-months/year
-
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$2,420
Cost:
$27,500
$600 15,600 $1,200 62 $620 - $600
15,600
kWh
$1,200
62
kW-months/year
$620
-
$
TOTAL RECOMMENDED Savings:
$7,890
Cost:
$35,980
$1,490 38,800 $5,780 299 $620 - $1,490
38,800
kWh
$5,780
299
kW-months/year
$620
-
$
TOTAL IMPLEMENTED Savings:
$3,440
Cost:
$1,120
$690 18,100 $2,750 142 - - $690
18,100
kWh
$2,750
142
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes