Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2011 |
Principal Product | Fabric tension structures |
NAICS | 314910 - Textile Bag and Canvas Mills |
SIC | 2394 - Canvas And Related Products |
Sales | $5,000,000-$10,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 76,000 |
Annual Production | 1,000 Pieces |
Production Hrs. Annual | 2,871 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $38,908 | 587,440 | kWh | $0.07 |
Electricity Demand | $27,670 | 3,278 | kW-months/year | $8.44 |
Electricity Fees | $4,236 | - | $ | - |
Natural Gas | $43,931 | 4,591 | MMBtu | $9.57 |
TOTAL ENERGY COSTS | $114,745 | |||
RECOMMENDED SAVINGS* | $32,080 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.512 CONDENSE OPERATION INTO ONE BUILDING |
Savings: $17,750 Cost: $20,000 |
$1,520 | 66,200 | $8,700 | 103 | $1,660 | - | $5,870 | 591 | - | - | - | - |
$1,520 66,200 kWh |
$8,700 103 kW-months/year |
$1,660 - $ |
$5,870 591 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,300 Cost: $110 |
$740 | 12,000 | $560 | 50 | - | - | - | - | - | - | - | - |
$740 12,000 kWh |
$560 50 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,530 Cost: $31,210 |
$6,380 | 91,400 | $2,920 | 471 | - | - | - | - | $130 | - | $100 | - |
$6,380 91,400 kWh |
$2,920 471 kW-months/year |
- - $ |
- - MMBtu |
$130 - $ |
$100 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $2,470 Cost: $20,920 |
$(-260) | (-3,600) | $(-100) | (-20) | - | - | $2,830 | 344 | - | - | - | - |
$(-260) (-3,600) kWh |
$(-100) (-20) kW-months/year |
- - $ |
$2,830 344 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,030 Cost: $90 |
$570 | 9,300 | $440 | 39 | - | - | - | - | $20 | - | - | - |
$570 9,300 kWh |
$440 39 kW-months/year |
- - $ |
- - MMBtu |
$20 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,080 Cost: $72,330 |
$8,950 | 175,300 | $12,520 | 643 | $1,660 | - | $8,700 | 935 | $150 | - | $100 | - | $8,950 175,300 kWh |
$12,520 643 kW-months/year |
$1,660 - $ |
$8,700 935 MMBtu |
$150 - $ |
$100 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Ancillary Material Cost |