Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2013 |
Principal Product | Fiberglass Light Poles |
NAICS | 335129 - Other Lighting Equipment Manufacturing |
SIC | 3648 - Lighting Equipment, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 154,250 |
Annual Production | 12,000 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,495 | 751,129 | kWh | $0.04 |
Electricity Demand | $56,516 | 2,664 | kW-months/year | $21.21 |
Electricity Fees | $628 | - | $ | - |
Natural Gas | $21,030 | 3,309 | MMBtu | $6.36 |
TOTAL ENERGY COSTS | $108,669 | |||
RECOMMENDED SAVINGS* | $11,450 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,780 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,670 Cost: $2,740 |
$370 | 8,500 | $2,300 | 106 | - | - | - | - | - | - | - | - |
$370 8,500 kWh |
$2,300 106 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,020 Cost: $250 |
$520 | 11,900 | $1,500 | 69 | - | - | - | - | - | - | - | - |
$520 11,900 kWh |
$1,500 69 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $730 Cost: $900 |
- | - | - | - | $730 | 109 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$730 109 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,190 Cost: $3,000 |
$940 | 21,800 | $2,010 | 93 | - | - | $120 | - | - | - | $120 | - |
$940 21,800 kWh |
$2,010 93 kW-months/year |
- - MMBtu |
$120 - $ |
- - $ |
$120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,840 Cost: $500 |
- | - | - | - | - | - | - | - | $2,840 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$2,840 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,450 Cost: $7,390 |
$1,830 | 42,200 | $5,810 | 268 | $730 | 109 | $120 | - | $2,840 | - | $120 | - | $1,830 42,200 kWh |
$5,810 268 kW-months/year |
$730 109 MMBtu |
$120 - $ |
$2,840 - $ |
$120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,780 Cost: $4,650 |
$1,460 | 33,700 | $3,510 | 162 | $730 | 109 | $120 | - | $2,840 | - | $120 | - | $1,460 33,700 kWh |
$3,510 162 kW-months/year |
$730 109 MMBtu |
$120 - $ |
$2,840 - $ |
$120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |