Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2015 |
Principal Product | Roofing Asphalt |
NAICS | 324122 - Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 12 |
Plant Area (Sq.Ft.) | 43,560 |
Annual Production | 400,000 Pounds |
Production Hrs. Annual | 2,340 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $26,007 | 577,920 | kWh | $0.05 |
Electricity Demand | $60,295 | 2,854 | kW-months/year | $21.13 |
Electricity Fees | $606 | - | $ | - |
Natural Gas | $130,964 | 21,872 | MMBtu | $5.99 |
TOTAL ENERGY COSTS | $217,872 | |||
RECOMMENDED SAVINGS* | $57,570 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,760 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $32,810 Cost: $82,650 |
$8,860 | 197,600 | $23,950 | 1,140 | - | - | - | - | - | - |
$8,860 197,600 kWh |
$23,950 1,140 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $19,610 Cost: $20,000 |
- | - | - | - | $19,610 | 3,365 | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,610 3,365 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,920 Cost: $3,750 |
$1,240 | 27,700 | $2,680 | 128 | - | - | - | - | - | - |
$1,240 27,700 kWh |
$2,680 128 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,230 Cost: $2,460 |
$660 | 14,800 | - | - | - | - | $120 | - | $450 | - |
$660 14,800 kWh |
- - kW-months/year |
- - MMBtu |
$120 - $ |
$450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $57,570 Cost: $108,860 |
$10,760 | 240,100 | $26,630 | 1,268 | $19,610 | 3,365 | $120 | - | $450 | - | $10,760 240,100 kWh |
$26,630 1,268 kW-months/year |
$19,610 3,365 MMBtu |
$120 - $ |
$450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,760 Cost: $26,210 |
$1,900 | 42,500 | $2,680 | 128 | $19,610 | 3,365 | $120 | - | $450 | - | $1,900 42,500 kWh |
$2,680 128 kW-months/year |
$19,610 3,365 MMBtu |
$120 - $ |
$450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |