Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2015 |
Principal Product | Kitchen and bath cabinets |
NAICS | 337110 - Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434 - Wood Kitchen Cabinets |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 41,500 |
Annual Production | 15,000 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $46,152 | 695,203 | kWh | $0.07 |
Electricity Demand | $55,791 | 2,625 | kW-months/year | $21.25 |
Electricity Fees | $986 | - | $ | - |
Natural Gas | $16,915 | 2,135 | MMBtu | $7.92 |
TOTAL ENERGY COSTS | $119,844 | |||
RECOMMENDED SAVINGS* | $43,320 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,720 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,710 Cost: $28,880 |
$5,270 | 82,200 | $2,440 | 100 | - | - | - | - | - | - |
$5,270 82,200 kWh |
$2,440 100 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,510 Cost: $1,200 |
$3,900 | 60,800 | $3,610 | 148 | - | - | - | - | - | - |
$3,900 60,800 kWh |
$3,610 148 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,400 Cost: $1,670 |
$690 | 10,800 | $710 | 29 | - | - | - | - | - | - |
$690 10,800 kWh |
$710 29 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $25,210 Cost: $57,920 |
$10,040 | 156,700 | $11,480 | 470 | - | - | $2,570 | - | $1,120 | - |
$10,040 156,700 kWh |
$11,480 470 kW-months/year |
- - MMBtu |
$2,570 - $ |
$1,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9111 USE SOLAR HEAT TO HEAT MAKE-UP AIR |
Savings: $1,490 Cost: $9,550 |
- | - | - | - | $1,490 | 209 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,490 209 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,320 Cost: $99,220 |
$19,900 | 310,500 | $18,240 | 747 | $1,490 | 209 | $2,570 | - | $1,120 | - | $19,900 310,500 kWh |
$18,240 747 kW-months/year |
$1,490 209 MMBtu |
$2,570 - $ |
$1,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,720 Cost: $59,120 |
$13,940 | 217,500 | $15,090 | 618 | - | - | $2,570 | - | $1,120 | - | $13,940 217,500 kWh |
$15,090 618 kW-months/year |
- - MMBtu |
$2,570 - $ |
$1,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |