IAC Center | Colorado State University |
---|---|
Assessment Year | 2021 |
Principal Product | Specialty turbomachinery |
NAICS | 333996 - Fluid Power Pump and Motor Manufacturing |
SIC | 3594 - Fluid Power Pumps And Motors |
Sales | $50,000,000-$100,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 5,500 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,764 | 1,764,194 | kWh | $0.05 |
Electricity Demand | $91,554 | 5,846 | kW-months/year | $15.66 |
Electricity Fees | $16,440 | - | $ | - |
Natural Gas | $19,561 | 2,584 | MMBtu | $7.57 |
TOTAL ENERGY COSTS | $222,319 | |||
RECOMMENDED SAVINGS* | $94,112 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,629 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $83,984 Cost: $462,079 |
$43,845 | 816,253 | $9,530 | 608 | $30,609 | - |
$43,845 816,253 kWh |
$9,530 608 kW-months/year |
$30,609 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,833 Cost: $2,733 |
$2,343 | 43,626 | $1,490 | 95 | - | - |
$2,343 43,626 kWh |
$1,490 95 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,478 Cost: $359 |
$1,478 | 27,515 | - | - | - | - |
$1,478 27,515 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,318 Cost: $16,143 |
$1,709 | 31,830 | $1,609 | 103 | - | - |
$1,709 31,830 kWh |
$1,609 103 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,499 Cost: $200 |
$374 | 6,961 | $1,125 | 72 | - | - |
$374 6,961 kWh |
$1,125 72 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $94,112 Cost: $481,514 |
$49,749 | 926,185 | $13,754 | 878 | $30,609 | - | $49,749 926,185 kWh |
$13,754 878 kW-months/year |
$30,609 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,629 Cost: $19,235 |
$5,530 | 102,971 | $3,099 | 198 | - | - | $5,530 102,971 kWh |
$3,099 198 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |