Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Case Western Reserve University |
---|---|
Assessment Year | 2022 |
Principal Product | Excavators and Vacuum Trucks |
NAICS | 333120 - Construction Machinery Manufacturing |
SIC | 3531 - Construction Machinery |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 422,753 |
Annual Production | 6,507 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $335,641 | 4,389,000 | kWh | $0.08 |
Natural Gas | $272,862 | 123,540 | MMBtu | $2.21 |
TOTAL ENERGY COSTS | $618,192 | |||
RECOMMENDED SAVINGS* | $199,286 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Usage | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Natural Gas | Water Usage | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $11,974 Cost: $2,500 |
- | - | - | - | $5,868 | 423 | $6,106 | 432 | - | - |
- - kWh |
- - MMBtu |
$5,868 423 Tgal |
$6,106 432 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,767 Cost: $400 |
$299 | 3,929 | $3,469 | 1,570 | - | - | - | - | - | - |
$299 3,929 kWh |
$3,469 1,570 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.2173 CONVERT TO ROBOTIC PAINTING |
Savings: $102,960 Cost: $48,500 |
- | - | - | - | - | - | - | - | $102,960 | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
$102,960 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $25,171 Cost: $73,990 |
$25,171 | 331,200 | - | - | - | - | - | - | - | - |
$25,171 331,200 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $13,037 Cost: $60,000 |
$13,037 | 171,543 | - | - | - | - | - | - | - | - |
$13,037 171,543 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE |
Savings: $42,376 Cost: $188,648 |
- | - | $42,376 | 19,196 | - | - | - | - | - | - |
- - kWh |
$42,376 19,196 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $199,286 Cost: $374,038 |
$38,507 | 506,672 | $45,845 | 20,765 | $5,868 | 423 | $6,106 | 432 | $102,960 | - | $38,507 506,672 kWh |
$45,845 20,765 MMBtu |
$5,868 423 Tgal |
$6,106 432 Tgal |
$102,960 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Usage | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Natural Gas | Water Usage | Water Disposal | One-time Revenue or Avoided Cost |