IAC logo
IAC Assessment: DL0001
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0001
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2007
Principal Product Injection Molded Plastic Parts
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 100,000
Annual Production 1,767,000,000 Pieces
Production Hrs. Annual 8,640
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,245,712 15,852,058 kWh $0.08
Electricity Demand $177,637 29,253 kW-months/year $6.07
Electricity Fees $5,649 - $ -
Natural Gas $4,378 261 MMBtu $16.77
TOTAL ENERGY COSTS $1,433,376
RECOMMENDED SAVINGS* $245,876 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $71,262
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$93,802
Cost:
$111,140
$93,802 915,506 - - $93,802
915,506
kWh
-
-
kW-months/year
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$12,151
Cost:
$13,790
$11,544 112,668 $607 21 $11,544
112,668
kWh
$607
21
kW-months/year
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$59,111
Cost:
$104,392
$57,242 558,685 $1,869 65 $57,242
558,685
kWh
$1,869
65
kW-months/year
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$44,733
Cost:
$12,474
$44,733 436,590 - - $44,733
436,590
kWh
-
-
kW-months/year
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,582
Cost:
$620
$3,582 33,861 - - $3,582
33,861
kWh
-
-
kW-months/year
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$29,521
Cost:
-
$29,521 288,125 - - $29,521
288,125
kWh
-
-
kW-months/year
07: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$2,976
Cost:
$5,832
$2,976 29,044 - - $2,976
29,044
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$245,876
Cost:
$248,248
$243,400 2,374,479 $2,476 86 $243,400
2,374,479
kWh
$2,476
86
kW-months/year
TOTAL IMPLEMENTED Savings:
$71,262
Cost:
$118,182
$68,786 671,353 $2,476 86 $68,786
671,353
kWh
$2,476
86
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand