IAC logo
IAC Assessment: DL0015
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0015
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2008
Principal Product Beer
NAICS 312120 - Breweries
SIC 2082 - Malt Beverages
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 50,000
Annual Production 180,000 Pieces
Production Hrs. Annual 8,766
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $14,029 180,008 kWh $0.08
Electricity Demand $2,800 383 kW-months/year $7.31
Other Energy $313,000 16,200 MMBtu $19.32
TOTAL ENERGY COSTS $329,829
RECOMMENDED SAVINGS* $96,800 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $31,430
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Energy Electricity Usage Electricity Demand Other Energy
$ kWh $ kW-months/year $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$20,000
Cost:
$400
- - - - $20,000 990 -
-
kWh
-
-
kW-months/year
$20,000
990
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,400
Cost:
$3,500
- - $2,400 25,000 - - -
-
kWh
$2,400
25,000
kW-months/year
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$19,500
Cost:
$20,000
$19,500 210,000 - - - - $19,500
210,000
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.7131 ADD AREA LIGHTING SWITCHES Savings:
$370
Cost:
$1,500
$370 4,000 - - - - $370
4,000
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$5,911
Cost:
$2,500
- - - - $5,911 306 -
-
kWh
-
-
kW-months/year
$5,911
306
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$14,000
Cost:
$16,000
- - - - $14,000 720 -
-
kWh
-
-
kW-months/year
$14,000
720
MMBtu
07: 2.1224 REPLACE BOILER Savings:
$13,000
Cost:
$20,000
- - - - $13,000 660 -
-
kWh
-
-
kW-months/year
$13,000
660
MMBtu
08: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$15,400
Cost:
$27,000
- - - - $15,400 780 -
-
kWh
-
-
kW-months/year
$15,400
780
MMBtu
09: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$2,970
Cost:
$10,000
- - - - $2,970 150 -
-
kWh
-
-
kW-months/year
$2,970
150
MMBtu
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,249
Cost:
$18,000
$3,249 34,938 - - - - $3,249
34,938
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$96,800
Cost:
$118,900
$23,119 248,938 $2,400 25,000 $71,281 3,606 $23,119
248,938
kWh
$2,400
25,000
kW-months/year
$71,281
3,606
MMBtu
TOTAL IMPLEMENTED Savings:
$31,430
Cost:
$45,500
$23,119 248,938 $2,400 25,000 $5,911 306 $23,119
248,938
kWh
$2,400
25,000
kW-months/year
$5,911
306
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Other Energy Electricity Usage Electricity Demand Other Energy