Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2008 |
Principal Product | Beer |
NAICS | 312120 - Breweries |
SIC | 2082 - Malt Beverages |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 180,000 Pieces |
Production Hrs. Annual | 8,766 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,029 | 180,008 | kWh | $0.08 |
Electricity Demand | $2,800 | 383 | kW-months/year | $7.31 |
Other Energy | $313,000 | 16,200 | MMBtu | $19.32 |
TOTAL ENERGY COSTS | $329,829 | |||
RECOMMENDED SAVINGS* | $96,800 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,430 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Energy | Electricity Usage | Electricity Demand | Other Energy | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $20,000 Cost: $400 |
- | - | - | - | $20,000 | 990 |
- - kWh |
- - kW-months/year |
$20,000 990 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,400 Cost: $3,500 |
- | - | $2,400 | 25,000 | - | - |
- - kWh |
$2,400 25,000 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,500 Cost: $20,000 |
$19,500 | 210,000 | - | - | - | - |
$19,500 210,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $370 Cost: $1,500 |
$370 | 4,000 | - | - | - | - |
$370 4,000 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $5,911 Cost: $2,500 |
- | - | - | - | $5,911 | 306 |
- - kWh |
- - kW-months/year |
$5,911 306 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $14,000 Cost: $16,000 |
- | - | - | - | $14,000 | 720 |
- - kWh |
- - kW-months/year |
$14,000 720 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1224 REPLACE BOILER |
Savings: $13,000 Cost: $20,000 |
- | - | - | - | $13,000 | 660 |
- - kWh |
- - kW-months/year |
$13,000 660 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $15,400 Cost: $27,000 |
- | - | - | - | $15,400 | 780 |
- - kWh |
- - kW-months/year |
$15,400 780 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $2,970 Cost: $10,000 |
- | - | - | - | $2,970 | 150 |
- - kWh |
- - kW-months/year |
$2,970 150 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,249 Cost: $18,000 |
$3,249 | 34,938 | - | - | - | - |
$3,249 34,938 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $96,800 Cost: $118,900 |
$23,119 | 248,938 | $2,400 | 25,000 | $71,281 | 3,606 | $23,119 248,938 kWh |
$2,400 25,000 kW-months/year |
$71,281 3,606 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,430 Cost: $45,500 |
$23,119 | 248,938 | $2,400 | 25,000 | $5,911 | 306 | $23,119 248,938 kWh |
$2,400 25,000 kW-months/year |
$5,911 306 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Energy | Electricity Usage | Electricity Demand | Other Energy |