IAC logo
IAC Assessment: DL0030
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0030
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2008
Principal Product metal
NAICS 423510 - Metal Service Centers and Other Metal Merchant Wholesalers
SIC 5051 - Metals Service Centers And Offices
Sales <$500,000
# of Employees 55
Plant Area (Sq.Ft.) 39,000
Annual Production 1 Units
Production Hrs. Annual 6,240
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $134,436 1,109,040 kWh $0.12
Natural Gas $71,172 4,852 MMBtu $14.67
TOTAL ENERGY COSTS $205,608
RECOMMENDED SAVINGS* $40,963 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $28,473
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1224 REPLACE BOILER Savings:
$5,600
Cost:
-
- - $5,600 398 -
-
kWh
$5,600
398
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$16,055
Cost:
$25,852
$16,055 127,420 - - $16,055
127,420
kWh
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,623
Cost:
$5,306
$1,623 13,416 - - $1,623
13,416
kWh
-
-
MMBtu
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$6,890
Cost:
$7,500
- - $6,890 500 -
-
kWh
$6,890
500
MMBtu
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$10,675
Cost:
-
$10,675 7,666 - - $10,675
7,666
kWh
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$120
Cost:
$140
$120 955 - - $120
955
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$40,963
Cost:
$38,798
$28,473 149,457 $12,490 898 $28,473
149,457
kWh
$12,490
898
MMBtu
TOTAL IMPLEMENTED Savings:
$28,473
Cost:
$31,298
$28,473 149,457 - - $28,473
149,457
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas