Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2009
Principal Product Men’s Tailored Clothing
NAICS 315220 - Men’s and Boys’ Cut and Sew Apparel Manufacturing
SIC 2311 - Men's and Boys' Suits, Coats, and Overcoats
Sales $50,000,000-$100,000,000
# of Employees 385
Plant Area (Sq.Ft.) 65,000
Annual Production 70,000 Pieces
Production Hrs. Annual 6,240
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $232,756 1,709,400 kWh $0.14
Natural Gas $109,285 10,989 MMBtu $9.94
TOTAL ENERGY COSTS $342,041
RECOMMENDED SAVINGS* $30,945 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $27,349
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE Savings:
$1,091
Cost:
-
- - $1,091 112 -
-
kWh
$1,091
112
MMBtu
02: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$5,409
Cost:
$9,300
$5,409 39,480 - - $5,409
39,480
kWh
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,789
Cost:
$16,100
$8,789 64,156 - - $8,789
64,156
kWh
-
-
MMBtu
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,737
Cost:
$10,000
- - $4,737 477 -
-
kWh
$4,737
477
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$580
Cost:
$80
$580 4,155 - - $580
4,155
kWh
-
-
MMBtu
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$3,596
Cost:
$12,500
$3,596 26 - - $3,596
26
kWh
-
-
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$310
Cost:
$150
$310 2,290 - - $310
2,290
kWh
-
-
MMBtu
08: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS Savings:
$6,433
Cost:
$26,980
$6,433 47,304 - - $6,433
47,304
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$30,945
Cost:
$75,110
$25,117 157,411 $5,828 589 $25,117
157,411
kWh
$5,828
589
MMBtu
TOTAL IMPLEMENTED Savings:
$27,349
Cost:
$62,610
$21,521 157,385 $5,828 589 $21,521
157,385
kWh
$5,828
589
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas