Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2009
Principal Product Metal Light Gauge Rolling
NAICS 331318 - Other Aluminum Rolling, Drawing, and Extruding
SIC 3355 - Aluminum Rolling And Drawing, Nec
Sales $100,000,000-$500,000,000
# of Employees 113
Plant Area (Sq.Ft.) 99,000
Annual Production 27,000 Tons
Production Hrs. Annual 8,430
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,916,740 16,962,305 kWh $0.11
Natural Gas $1,458,268 102,695 MMBtu $14.20
TOTAL ENERGY COSTS $3,375,008
RECOMMENDED SAVINGS* $197,803 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$89,460
Cost:
$41,150
- - $89,460 6,300 -
-
kWh
$89,460
6,300
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$31,002
Cost:
$5,550
- - $31,002 1,747 -
-
kWh
$31,002
1,747
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$21,300
Cost:
$575
- - $21,300 1,500 -
-
kWh
$21,300
1,500
MMBtu
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$12,400
Cost:
$950
$12,400 110,000 - - $12,400
110,000
kWh
-
-
MMBtu
05: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE Savings:
$6,452
Cost:
-
$6,452 57,093 - - $6,452
57,093
kWh
-
-
MMBtu
06: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY Savings:
$37,189
Cost:
$70,000
$37,189 329,107 - - $37,189
329,107
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$197,803
Cost:
$118,225
$56,041 496,200 $141,762 9,547 $56,041
496,200
kWh
$141,762
9,547
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas