Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2011
Principal Product Magnesium chips, powders and pieces.
NAICS 331492 - Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
SIC 3399 - Primary Metal Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 33
Plant Area (Sq.Ft.) 1,524,600
Annual Production 1,500,000 Pounds
Production Hrs. Annual 4,160
Location (State) NJ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $443,381 2,450,970 kWh $0.18
Natural Gas $7,195 480 MMBtu $14.99
LPG $6,422 430 MMBtu $14.93
TOTAL ENERGY COSTS $456,998
RECOMMENDED SAVINGS* $59,454 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,314
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$14,500
Cost:
$30,600
$14,500 80,000 $14,500
80,000
kWh
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,000
Cost:
$22,400
$8,000 44,000 $8,000
44,000
kWh
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$5,460
Cost:
$3,680
$5,460 30,000 $5,460
30,000
kWh
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$3,970
Cost:
$1,158
$3,970 21,800 $3,970
21,800
kWh
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$22,650
Cost:
$328,687
$22,650 124,435 $22,650
124,435
kWh
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,834
Cost:
$2,409
$2,834 15,574 $2,834
15,574
kWh
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$1,530
Cost:
$3,280
$1,530 8,400 $1,530
8,400
kWh
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$510
Cost:
$50
$510 2,800 $510
2,800
kWh
TOTAL RECOMMENDED Savings:
$59,454
Cost:
$392,264
$59,454 327,009 $59,454
327,009
kWh
TOTAL IMPLEMENTED Savings:
$7,314
Cost:
$3,617
$7,314 40,174 $7,314
40,174
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage