Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2011
Principal Product Recycled press Fiberboard
NAICS 322130 - Paperboard Mills
SIC 2631 - Paperboard Mills
Sales $50,000,000-$100,000,000
# of Employees 140
Plant Area (Sq.Ft.) 500,000
Annual Production 99,999 Units
Production Hrs. Annual 8,760
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $3,199,591 44,102,220 kWh $0.07
Natural Gas $6,390,893 1,089,347 MMBtu $5.87
LPG $60,037 3,365 MMBtu $17.84
Fuel Oil #2 $18,153 1,040 MMBtu $17.45
TOTAL ENERGY COSTS $9,668,674
RECOMMENDED SAVINGS* $552,602 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $77,835
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1224 REPLACE BOILER Savings:
$123,207
Cost:
$900,000
- - $123,207 21,000 -
-
kWh
$123,207
21,000
MMBtu
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$191,452
Cost:
$500,000
- - $191,452 32,632 -
-
kWh
$191,452
32,632
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$30,553
Cost:
$42,800
$30,553 418,530 - - $30,553
418,530
kWh
-
-
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$57,285
Cost:
$28,500
$57,285 784,730 - - $57,285
784,730
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$33,872
Cost:
$165,720
$33,872 464,000 - - $33,872
464,000
kWh
-
-
MMBtu
06: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP Savings:
$14,637
Cost:
$800
$14,637 200,500 - - $14,637
200,500
kWh
-
-
MMBtu
07: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE Savings:
$77,835
Cost:
$42,650
$(-4,303) (-58,950) $82,138 14,000 $(-4,303)
(-58,950)
kWh
$82,138
14,000
MMBtu
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$23,761
Cost:
$22,500
- - $23,761 4,050 -
-
kWh
$23,761
4,050
MMBtu
TOTAL RECOMMENDED Savings:
$552,602
Cost:
$1,702,970
$132,044 1,808,810 $420,558 71,682 $132,044
1,808,810
kWh
$420,558
71,682
MMBtu
TOTAL IMPLEMENTED Savings:
$77,835
Cost:
$42,650
$(-4,303) (-58,950) $82,138 14,000 $(-4,303)
(-58,950)
kWh
$82,138
14,000
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas