IAC logo
IAC Assessment: DL0082
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DL0082
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2012
Principal Product Heterocyclic Hydrocarbons
NAICS 325199 - All Other Basic Organic Chemical Manufacturing
SIC 2869 - Industrial Organic Chemicals, Nec
Sales $500,000-$1,000,000
# of Employees 35
Plant Area (Sq.Ft.) 20,000
Annual Production 220 Pounds
Production Hrs. Annual 4,420
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $135,625 1,144,465 kWh $0.12
Natural Gas $83,435 6,550 MMBtu $12.74
TOTAL ENERGY COSTS $219,060
RECOMMENDED SAVINGS* $89,708 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,357
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7314 REDUCE VENTILATION AIR Savings:
$64,179
Cost:
$280,000
$32,844 276,000 $31,335 2,460 $32,844
276,000
kWh
$31,335
2,460
MMBtu
02: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR Savings:
$18,536
Cost:
$46,000
$3,887 32,667 $14,649 1,150 $3,887
32,667
kWh
$14,649
1,150
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,641
Cost:
$1,330
$4,641 39,000 - - $4,641
39,000
kWh
-
-
MMBtu
04: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$716
Cost:
$90
$716 6,000 - - $716
6,000
kWh
-
-
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,636
Cost:
$2,100
$1,636 13,750 - - $1,636
13,750
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$89,708
Cost:
$329,520
$43,724 367,417 $45,984 3,610 $43,724
367,417
kWh
$45,984
3,610
MMBtu
TOTAL IMPLEMENTED Savings:
$5,357
Cost:
$1,420
$5,357 45,000 - - $5,357
45,000
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas