Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2015 |
Principal Product | Printed Books |
NAICS | 323117 - Books Printing |
SIC | 2732 - Book Printing |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 1,000,000 |
Annual Production | 8,000,000 Pieces |
Production Hrs. Annual | 8,008 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,921,583 | 28,489,800 | kWh | $0.10 |
Electricity Demand | $231,962 | 48,216 | kW-months/year | $4.81 |
Electricity Fees | $431,275 | - | $ | - |
Natural Gas | $31,796 | 2,658 | MMBtu | $11.96 |
TOTAL ENERGY COSTS | $3,616,616 | |||
RECOMMENDED SAVINGS* | $1,137,225 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $913,520 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $19,390 Cost: - |
$18,240 | 177,100 | $1,150 | 240 | - | - |
$18,240 177,100 kWh |
$1,150 240 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7314 REDUCE VENTILATION AIR |
Savings: $11,465 Cost: - |
$4,430 | 43,050 | $495 | 103 | $6,540 | 547 |
$4,430 43,050 kWh |
$495 103 kW-months/year |
$6,540 547 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $178,010 Cost: $40,300 |
$167,330 | 1,624,590 | $10,680 | 2,220 | - | - |
$167,330 1,624,590 kWh |
$10,680 2,220 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7314 REDUCE VENTILATION AIR |
Savings: $7,060 Cost: $5,680 |
$6,640 | 64,500 | $420 | 88 | - | - |
$6,640 64,500 kWh |
$420 88 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,110 Cost: $21,440 |
$9,850 | 95,625 | $1,260 | 262 | - | - |
$9,850 95,625 kWh |
$1,260 262 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $154,200 Cost: $348,840 |
$144,920 | 1,407,000 | $9,280 | 1,930 | - | - |
$144,920 1,407,000 kWh |
$9,280 1,930 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $13,630 Cost: $31,200 |
- | - | - | - | $13,630 | 1,140 |
- - kWh |
- - kW-months/year |
$13,630 1,140 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $26,240 Cost: $75,600 |
$25,030 | 243,000 | $1,210 | 252 | - | - |
$25,030 243,000 kWh |
$1,210 252 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $678,100 Cost: $3,234,220 |
$652,220 | 6,332,250 | $25,880 | 5,380 | - | - |
$652,220 6,332,250 kWh |
$25,880 5,380 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $38,020 Cost: $217,230 |
$38,020 | 369,170 | - | - | - | - |
$38,020 369,170 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,137,225 Cost: $3,974,510 |
$1,066,680 | 10,356,285 | $50,375 | 10,475 | $20,170 | 1,687 | $1,066,680 10,356,285 kWh |
$50,375 10,475 kW-months/year |
$20,170 1,687 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $913,520 Cost: $3,491,750 |
$875,810 | 8,503,110 | $37,710 | 7,840 | - | - | $875,810 8,503,110 kWh |
$37,710 7,840 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |