Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2016 |
Principal Product | Carbonated Beverages |
NAICS | 312111 - Soft Drink Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | >$500,000,000 |
# of Employees | 1,000 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 62,400 Thousand Gallons |
Production Hrs. Annual | 6,006 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $715,588 | 10,624,770 | kWh | $0.07 |
Electricity Demand | $113,938 | 25,627 | kW-months/year | $4.45 |
Electricity Fees | $3,601 | - | $ | - |
Natural Gas | $152,739 | 34,176 | MMBtu | $4.47 |
TOTAL ENERGY COSTS | $1,580,568 | |||
RECOMMENDED SAVINGS* | $169,275 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $93,995 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $11,140 Cost: - |
$11,140 | 166,300 | - | - | - | - | - | - |
$11,140 166,300 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,860 Cost: $2,250 |
$3,450 | 51,510 | $410 | 92 | - | - | - | - |
$3,450 51,510 kWh |
$410 92 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $34,545 Cost: $41,405 |
- | - | - | - | - | - | $34,545 | 4,700,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$34,545 4,700,000 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $8,290 Cost: $11,760 |
$7,320 | 109,300 | $970 | 218 | - | - | - | - |
$7,320 109,300 kWh |
$970 218 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $48,630 Cost: $79,420 |
$39,060 | 582,930 | $9,570 | 2,150 | - | - | - | - |
$39,060 582,930 kWh |
$9,570 2,150 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $14,700 Cost: $44,740 |
- | - | - | - | $14,700 | 3,289 | - | - |
- - kWh |
- - kW-months/year |
$14,700 3,289 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $22,170 Cost: $77,500 |
$19,820 | 295,820 | $2,350 | 529 | - | - | - | - |
$19,820 295,820 kWh |
$2,350 529 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $14,500 Cost: $53,850 |
$6,300 | 94,080 | - | - | $8,200 | 1,835 | - | - |
$6,300 94,080 kWh |
- - kW-months/year |
$8,200 1,835 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,440 Cost: $46,960 |
$10,100 | 150,680 | $1,340 | 301 | - | - | - | - |
$10,100 150,680 kWh |
$1,340 301 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $169,275 Cost: $357,885 |
$97,190 | 1,450,620 | $14,640 | 3,290 | $22,900 | 5,124 | $34,545 | 4,700,000 | $97,190 1,450,620 kWh |
$14,640 3,290 kW-months/year |
$22,900 5,124 MMBtu |
$34,545 4,700,000 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $93,995 Cost: $210,605 |
$41,060 | 612,800 | $3,690 | 830 | $14,700 | 3,289 | $34,545 | 4,700,000 | $41,060 612,800 kWh |
$3,690 830 kW-months/year |
$14,700 3,289 MMBtu |
$34,545 4,700,000 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) |